Hoffman Specialty
Series 2000 Air and Spring
Pilot Replacement Parts
Models AP-1, AP-3, AP-5
and SP-12, SP-30, SP-60, SP-175, SP225
(Not currently manufactured)
PLEASE READ INSTRUCTIONS CAREFULLY BEFORE
STARTING WORK. ALL WORK MUST BE PERFORMED
BY QUALIFIED PERSONNEL IN ACCORDANCE WITH
ALL APPLICABLE CODES AND ORDINANCES.
BEFORE ANY VALVE SYSTEM IS DIS-
CAUTION:
ASSEMBLED
!
LINES WHICH COULD PRESSURIZE
ANY OF THE VALVE CHAMBERS. ANY
VALVE CHAMBER MAY HAVE HOT CON-
DENSATE TRAPPED, USE CAUTION
WHEN OPENING ANY SECTION OR
CHAMBER.
®
CLOSE
ALL
STEAM
INSTRUCTION MANUAL
Pressure Pilots
(SPRING AND AIR)
Remove the pilot from the main valve. In order to deter-
mine the malfunction before disassembling the valve, hook
the pilot to air and test. Attach shop air to the pilot inlet,
install a line with a shutoff valve and a pressure gauge at
the pilot outlet and plug the feed back port.
HS-613