What To Do If - Xylem WTW MIQ/CHV PLUS Operating Manual

Iq sensor net, valve module for compressed air-operated sensor cleaning head
Table of Contents

Advertisement

What to do if ...

6
No compressed air
Cause
at the output
– Compressed air supply inter-
– Supply voltage not present or
– Error in triggering
18
All manuals and user guides at all-guides.com
What to do if ...
rupted or too weak
too low
Remedy
– Check the compressed air supply
IQ S
N
:
ENSOR
ET
– See the chapter, W
HAT TO DO IF
system manual
– Perform the function check according to
section 3.6.
– If the valve does not switch, check the
control
– loose clamping connection
– broken control line
– defective relay output
– valve output was not linked with a
sensor (see system operating man-
ual)
– incorrect setting of the linked valve
output (see chapter 4)
ba75539d03
MIQ/CHV PLUS
... in the
03/2018