Kohler 24RCL Manual page 36

Residential/light commercial generator sets
Hide thumbs Also See for 24RCL:
Table of Contents

Advertisement

SiteTech Group
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset System
Configuration
Genset Calibration
Genset Calibration
Genset Calibration
Genset Calibration
Genset Calibration
Genset Calibration
Genset Calibration
Genset Calibration
Genset Calibration
Advanced Speed Control
Advanced Speed Control
* Read Only = Not adjustable
w Load management device (LCM, load shed kit, or RXT with combined interface/ load management board).
[ Notes indicate applicability to genset or accessories. N/A = Not applicable to the models covered in this manual.
] See TT-1584 for more information about digital inputs and outputs.
Grayed rows are visible in SiteTech but do not apply to all models.
36
Section 3 Controller
Parameter
ECM Power
Display Contrast
Genset System Language
Genset Maximum Percent
Capacity
Generator Overloaded Percent
Under Frequency Shed Level
Base Load Add Time
Base Over Load Shed Time
Base Under Frequency Shed
Time
Genset Fuel Type
Automatic Start Minimum
Voltage
Automatic Stop Minimum
Percent Load
Automatic Start Minimum
Voltage Delay
Automatic Stop Minimum Load
Delay
ECM Powered Mode
Genset Calibration Factor
Voltage L1-L2
Genset Calibration Factor
Voltage L2-L3
Genset Calibration Factor
Voltage L3-L1
Genset Calibration Factor
Current L1 -- N
Genset Calibration Factor
Current L1
Genset Calibration Factor
Current L2
Genset Calibration Factor
Current L3
Current Transformer Calibration
At No Load
Current Transformer Calibration
At Full Load
Proportional Gain
Transient Integral Gain
Adjustment
Range *
Units
On or Off
0 -- 100
0 -- 4
%
0 -- 120
%
0 -- 120
Hz
0 -- 5
s
10 -- 2400
s
2 -- 30
s
1 -- 20
Natural Gas or LP
(pulldown)
V
15 -- 60
%
0 -- 100
s
1 -- 3600
s
1 -- 3600
On or Off
0.9 -- 1.1
0.9 -- 1.1
0.9 -- 1.1
0.9 -- 1.1
0.9 -- 1.1
0.9 -- 1.1
0.9 -- 1.1
0 -- 100
0 -- 400
No effect.
No effect.
Default
Setting
Notes
[
Off
50
English
N/A
70.0
85.0
0.5
60
30
5
Natural Gas
51
20
180
180
Off
0.9811
0.9722
0.9717
1.000000
1.04
1.04
1.04
3.5
121.5
N/A
N/A
TP-6907 5/16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

30rcl38rclb

Table of Contents