Controller Parameters; Controller Parameters Table; Notes On Selected Parameters - Kohler 24RCL Manual

Residential/light commercial generator sets
Hide thumbs Also See for 24RCL:
Table of Contents

Advertisement

3.3 Controller Parameters

Adjustable parameter settings can be changed using a
personal computer (or laptop) with Kohlerr SiteTecht
software. See Section 3.2, SiteTech Software, for USB
connection information. See the SiteTech Operation
Manual, TP-6701, for general software operation
instructions.
Some settings can also be changed at the controller.
See the generator set operation manual for instructions
to navigate through the controller menus and change
settings.
1
2
1. Controller
2. Controller mounting screws (qty. 2)
Figure 3-3 Controller Location
30
Section 3 Controller
3.3.1

Controller Parameters Table

The table on the following pages lists controller
parameters that are visible in SiteTech. Settings marked
Read Only are not user-adjustable.
Some parameters that are visible in SiteTech do not
apply to all models. Those parameters are marked in
the last column, and the line in the table is shaded gray.
The table indicates the following:
Factory default settings
D
Adjustment range for adjustable settings
D
Note: Some settings are not user-adjustable.
Units for the setting (e.g. RPM)
D
The group in SiteTech that contains the parameter.
D
3.3.2

Notes on Selected Parameters

Genset Info
Model numbers and serial numbers are factory-set for
each unit. If the controller is replaced, the genset model
number and serial number will need to be entered by the
installer. For the genset model number, select the
appropriate model from the dropdown list. Find the
generator set serial number on the nameplate and enter
it using SiteTech.
See Section 3.5, Controller
Replacement, for information about other setup
required on a replacement controller.
Changing the genset model number will update the
engine model number automatically. Select the genset
model number and then click Apply Changes in SiteTech
to see the updated engine model number.
Genset Fuel Type
The Genset Fuel Type setting is located in the Genset
System Configuration group in SiteTech. Generator set
power and current ratings are different for different fuel
types (natural gas or Liquid Propane). The fuel type
setting is available with controller firmware versions 4.5
and higher.
Changing the Genset Fuel Type setting automatically
updates the Genset Power Rating and Genset Rated
Current settings. The power rating is used to determine
setpoints for the optional load management device. If a
load management device is connected and the
generator set is converted to a different fuel, use
SiteTech to change the Genset Fuel Type setting.
TP-6907 5/16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

30rcl38rclb

Table of Contents