7.10 Enclosure Reassembly

See Figure 7-12 for an illustration of enclosure parts.
Note: When reassembling the enclosure, do not
over-tighten the screws into the aluminum
enclosure panels.
into aluminum enclosure panels is 5.7 Nm (50 in. lbs.).
1. To attach the rear panel:
a. Position the rear panel on the skid.
b. Use four screws to secure the rear panel to the
skid.
c. Connect the engine snorkel to the air cleaner.
2. To attach the front panel:
a. Position the front panel on the skid.
b. Use two screws to secure the front panel to the
exhaust mounting bracket.
c. Use three screws to secure the front panel to
the skid.
1. Roof
2. Exhaust mounting bracket
3. Key, latch opening
4. Side panel
5. Front panel
6. Silencer
7. Door
8. Rear panel assembly
8
Note: Maximum torque for screws into aluminum
enclosure panels: 5.7 Nm (50 in. lbs.).
Figure 7-12 Enclosure
TP-6907 5/16
The maximum torque for screws
3. To attach the side panels:
a. Position the side panel.
b. Use two screws to secure the side panel to the
bulkhead.
c. Use one screw to secure the side panel to the
skid.
4. To attach the roof:
a. Position the roof and secure with fourteen
screws, three screws in each side and four on
each end.
5. To attach the doors:
a. Attach the ground cable on the back of the door.
b. Position the door.
c. Use the latch opening key to lock the door.
1
7
7
4
3
2
6
Section 7 Disassembly/Reassembly
4
5
GM91044