Watchport/D (Proximity & Distance Sensor) - Digi Inside Out Watchport Installation Manual

Monitoring appliances
Table of Contents

Advertisement

Watchport/D (Proximity & Distance Sensor)
The Watchport/D can be programmed to use either an RS-232 modem signal interface or an
ASCII command interface. In its ASCII command mode, the sensor reports the distance to the
object (if any). In its modem signal mode, the sensor acts as a 'proximity' detector; that is, if an
object comes within range, the sensor will raise (and then lower) its DSR signal. The default
mode is Proximity.
Command
Description
Tells about the command set available for this
?<CR>
Watchport.
Tells what kind of Watchport is connected.
I<CR>
For the ASCII command mode:
Reflects the current distance. The valid range is from
D<CR>
20 cm to 150 cm. Otherwise, the sensor indicates no
object.
For the modem signal mode:
Enables monitor function. Until any other
E<CR>
keystroke, the sensor uses DSR to signal 'proximity.'
Adjusts sensitivity M is followed by a single digit:
Mn<CR>
1 (most sensitive) through 9 (least sensitive).
Watchport Installation Guide (90000406 Rev. D) – Page 13
Watchport/D Commands
Return Value
as described in this
section
Watchport/D<CR>
nnncm<cr>
No Object<cr>
OK<CR>
OK<CR>