Watchport/T (Temperature Sensor) - Digi Inside Out Watchport Installation Manual

Monitoring appliances
Table of Contents

Advertisement

Watchport/T (Temperature Sensor)

The Watchport/T uses an ASCII command interface. Its operating range is -55C to +125C.
Command
Description
Tells about the command set available for this
?<CR>
Watchport.
Tells what kind of Watchport is connected.
I<CR>
Gives temperature in Celsius.
T<CR>
Also gives temperature in Celsius.
TC<CR>
Gives temperature in Fahrenheit.
TF<CR>
Repeats the TF commend every 3-4 seconds until the
TF+<CR>
next keystroke. Appending + also works with the TC and
T commands.
Adjusts the slew rate of the data line. When L is
L4<CR>
followed by a numeric value, 1 through 8, Watchport
responds with OK. Other values return Invalid
Command. The default setting is 4. Adjust the parameter
until the data transmission becomes error-free. The
setting remains in effect until the Watchport is power-
cycled.
Watchport Installation Guide (90000406 Rev. D) – Page 14
Watchport/T Commands
Return Value
as described in this
section
Watchport/T<CR>
+22.2500C<CR>
+22.2500C<CR>
+72.0000F<CR>
+72.0000F<CR>
OK
Invalid Command