Resetting Of The Factory Settings; Setting The Climatic Curve - Baxi PRIME Series Installation Manual

Condensing gas wall-hung boilers
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
DP020
Pump overrun time in DHW mode
DP034
Storage boiler sensor offset
DP035
ACS storage boiler pump start
DP060
DHW time program selected
DP070
Domestic hot water setpoint
DP080
DHW storage boiler reduced temperature setpoint
DP160
ACS anti-legionella set value
DP170
Holiday period start
DP180
Holiday period end
DP190
Off time modification
DHW mode:
- scheduling
DP200
- manual
- antifrost
- temporary
DP347
Enabling of DHW pre-heating with MK1
DP370
Holiday period DHW setpoint
GP007
Max fan speed in heating mode
GP008
Min fan speed
GP009
Fan starting speed
GP022
Average delivery temperature calculation factor
PP015
Pump overrun time in heating mode
PP016
Max pump speed in heating mode
PP023
Burner switching on hysteresis in heating mode
NOTE: the factory values of some parameters may differ depending on the country of destination of the product.
9.2

Resetting of the factory settings

Check and note down the CN1 and CN2 values on the data label (see chapter 5.3.1. ).
• Press
for 10 seconds, until the display shows "Cn";
• Press
, the display will show "1.0" (in the example, the second digit "0" flashing represents the value of "CN1");
• Press "RESET" to change the second digit to the "CN1" value indicated in the data label;
• Press
to confirm; the display will show "2.0" (in the example, the second digit "0" is the value of "CN2");
• Press "RESET" to change the second digit to the "CN2" value indicated in the data label;
• Press
to confirm; the display will show "End";
• Press "RESET" to exit the menu and in the case that other error codes appear;
• Turn the boiler off and then on again to run the automatic vent (5 min duration) and diagnostics procedure.
Any customised parameters, set before the reset to the factory configuration, will have to changed manually.
9.3

Setting the climatic curve

Connect the external probe to the X14 (OS) terminal and the "On/Off" type
ambient thermostat to terminal X8 as shown in the figure.
To change the curve set the following parameters:
• CP000 : maximum flow temperature setpoint (Tm).
• CP230 : changes the slope of the curve (from 0,0 to 4,0).
• CP210 : changes the value (offset) of the minimum flow
temperature (Tm). Does not change the slope of the curve.
Te
External temperature (°C)
Tm
Heating flow temperature (°C)
The parameters for setting the climate curve can only be
changed using the Service-Tool (see paragraph 9.1).
15
0°C
-2°C
Prog.1
60
15°C
65°C
-
-
-
antifrost
Disabled
10°C
6200 (20kW)
7300 (24kW)
2200
3800
1
2
85
10
CP000
80
75
70
65
60
55
50
45
40
35
30
25
CP210
20
20
15
10
37
0
99
0°C
10°C
-20°C
20°C
Prog.2
Cooling
35
60
7°C
50°C
50°C
90°C
-
-
-
-
-
-
-
-
Enabled with
Enabled
OT settings
10°C
60°C
1800
9500
1800
4000
1800
6000
1
50
0
99
20
100
1
10
X8
X14
On/Off
OS
1,5
4,0
3,0
2,0
5
0
-5
-10
-15
-20
Te
(°C)
BO-0000056
7696306 (01-12/17)
service
service
service
user
user
user
service
user
user
user
service
service
user
service
service
service
service
service
service
service
BO-0000153
1,0
0,5
-25
-30