Example of separate duct installations
L
1
The length of the outlets is shown in the table of paragraph 6.5.4.
6.5.4
Lengths of the air-fume ducts
In order to identify the maximum length of the suction and evacuation ducts, refer to the table shown below.
L = L2 + L1
VERSION TYPE B23-B23P-B33-C13-C33-C43-C53-C83-C93
Ø
[mm]
80-80
60/100
80/125
80-50 *
80-60 **
*
50 mm diameter of the rigid and flexible flue duct
**
60 mm diameter of the rigid flue duct
*** with this type of flue duct it is necessary to lowering the power the appliance to 28 kW (see table below "Modification of the parameters ...")
In "B" type installations, the installation room must have the necessary supply air openings. These must not be reduced or
closed.
Specific adapters are available as accessories for exhausts 80/125, 80/50, 80/60.
7696306 (01-12/17)
L
2
L
BO-0000078
PRIME 1.24 PRIME 1.24 PRIME 1.24
L Max [m]
L2 Max [m]
L1 MAX [m]
80
15
LMax-L1
10
-
-
25
-
-
30
30
10
40
30
10
L
L
PRIME 26
PRIME 26
PRIME 26
L Max [m]
L2 Max [m]
L1 Max [m]
80
15
LMax-L1
10
-
-
25
-
-
40
25
10
40
30
10
26
BO-0000055
PRIME 30
PRIME 30
PRIME 30
L Max [m]
L2 Max [m]
L1 Max [m]
80
15
LMax-L1
10
-
-
25
-
-
30***
20***
10
40***
30***
10