TECHNICAL DATA
Limit values:
- minimum revs
- maximum revs
- minimum supply voltage
- maximum supply voltage
- max. supply voltage for 1 minute
- current draw
Circuit is protected against reverse supply voltage (wrong connection).
Features:
- CDI charged from hi voltage charging coils (generator)
- programmable ignition map (3D interpolated)
- store and load function for 2 ignition maps
- one input for magnetic pickup
- TPS input (ignition map is 3D interpolated above TPS33%)
- external switch for changing ignition map while riding
- power jet output
- shift light output
- quick shift (shift kill)
- tachometer output
- advance/retard whole ignition curve
- three stage rev limit (retard timing, reduced spark, spark off)
- signal delay compensation
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...)
- easy and fast programming on the field, via hand held programmer
- programming while machine running - you can immediately see effects
- monitoring of rev's, TPS position, ignition advance angle, via LCD(hand held programmer)
- fast processing for high accuracy - delays from 1us
USER MANUAL
PCDI-RGT
PROGRAMMABLE CDI IGNITION
- 1 -
200 RPM
20000 RPM
8 Volts
16 Volts
35 Volts
25 mAmp

Advertisement

loading

Summary of Contents for zeeltronic PCDI-RGT

  • Page 1 03.04.2013 firmware version: 20.130327 USER MANUAL PCDI-RGT PROGRAMMABLE CDI IGNITION TECHNICAL DATA Limit values: - minimum revs 200 RPM - maximum revs 20000 RPM - minimum supply voltage 8 Volts - maximum supply voltage 16 Volts - max. supply voltage for 1 minute...
  • Page 2 HOW TO ENTER MENU PCDI must be connected to power supply. Connect programmer to PCDI and wait few seconds for activation of programmer and then press enter. With pressing + or - you can move through menu and select with pressing enter . Exit menu with selecting Exit.
  • Page 3 SET IGNITION MAP (if TPS disabled) Enter Set Ign. menu and move to Set Ignition Map with pressing + or - and then press enter..you entered submenu for setting ignition map. Submenu organisation: Nr. of Points - number of ignition curve points (from 4 to 12) - first ignition curve point - second ignition curve point Exit...
  • Page 4 5.1. SET IGNITION MAP (if TPS enabled) Three ignition curves must be programmed for different TPS positions. PDCI does not only switch between ignition curves, but also interpolate 3D map for all TPS positions above 33%. Enter Set Ign. menu and move to Set Ignition Map with pressing + or - and then press enter.
  • Page 5 Set ADVANCE With this setting is possible to advance or retard whole ignition curve. When setting is positive then ignition curve is advanced and when setting is negative than ignition curve is retarded. With Advance 0.0deg, ignition curve is unchanged. Enter menu and move to Advance with pressing + or - and then press enter .
  • Page 6 Set REV LIMIT Enter menu and move to Rev Limit with pressing + or - and then press enter . Now you can change rev limit with pressing + or - (in 100 rpm steps) and then press enter . Set STATIC ANGLE Enter menu and move to Static Angle with pressing + or - and then press enter .
  • Page 7 Set TPS open [100%] For correct operation, TPS open position must be calibrated! Enter menu and move to TPS open [100%] with pressing + or - and then press enter . Move throttle to maximum open position and confirm calibrating with pressing enter , or exit calibration with pressing -.
  • Page 8 When "only [+] signal" is checked, then only positive signal is detected and ignition timing is calculated with all revs as programmed with ignition map. When "[+] and [-] signal" is checked, then both signals are detected. Revs of first ignition point define switching point between, programmed ignition map and idle running timing position.
  • Page 9 MONITORING Connect programmer to PCDI and wait few seconds for activation of programmer. Fist information displayed on the programmer is firmware version. With programmer you can watch revs, calculated advance ignition angle and TPS position. Information! You can connect or disconnect PCDI unit from programmer any time you want, without any harm.