21
USER MANUAL BATMODE 2S/2S+ SYSTEM
connectors of the GM50 microphone discs. Due to different pin numbers, it is not possible to
connect the microphone cable incorrectly. If you are using GM90 microphone discs, use the
microphone cables to connect the microphone inputs of the UltraSoundGate to the
microphone connector of the GM90 microphone discs.
When using tower microphones TM10 or TM20, connect the built-in cables to the XLR
microphone inputs of the UltraSoundGate.
3. If you utilize GM90 microphone discs, contact the microphone heaters of the microphone discs
by connecting the USB heating cables to the USB power plugs and plug them into a 230V outlet.
4. Exclusively BATmode 2S:
Connect the cellular antenna to the cellular antenna connector of the BATmode 2S.
Exclusively BATmode 2S+:
Connect the antenna wires with the corresponding connectors at the BATmode 2S+ and the
antenna disc.
Ensure not to interchange both wires. This would cause declined signal reception levels of the
WIFI and cellular network connection.
5. Exclusively BATmode 2S+:
Use the temperature sensor cable to connect the analog temperature sensor input of the
BATmode 2S+ with the corresponding temperature sensor output of the antenna disc.
6. Exclusively BATmode 2S+:
7. Optionally, precipitation data can be acquired by the BATmode 2S+ via the analog input or
USB/RS485 or USB/RS422 interface. For this purpose, a precipitation sensor has to be
connected to BATmode 2S+. For connecting, please refer to the manual of the precipitation
sensor.
8. To simplify the parameterization of the BATmode system peripheral pc devices (mouse,
keyboard, screens...) can be connected to the free USB and Minidisplay ports, optionally.
9. If it is intended to use wired LAN connection to remotely access the BATmode system, connect
a corresponding Ethernet cable to the LAN port (RJ45, not included in delivery) of the
BATmode.
10. Finally, connect the power supply to the BATmode.
Please note that microphone discs GM90 with a heating connection marked
with "5V" have to be operated only via USB heating cables and not via the
heating output of the BATmode. Violation may result in the destruction of the
microphone heater and equipment failure and damage, as well as data loss.
Only use authorized precipitation sensors und connection wires, since the use
of different devices can cause system failure, damage and loss of data.