When Measuring At Multiple Measuring Points With An Ultrasoundgate 416Hnbm - BAT BATmode 2S User Manual

Table of Contents

Advertisement

20
USER MANUAL BATMODE 2S/2S+ SYSTEM
4. If you utilize GM90 microphone discs, contact the microphone heaters of the microphone discs
by connecting the USB heating cables to the USB power plugs and plug them into a 230V outlet.
5. Exclusively BATmode 2S:
Connect the cellular antenna to the cellular antenna connector of the BATmode 2S.
Exclusively BATmode 2S+:
Connect the antenna wires with the corresponding connectors at the BATmode 2S+ and the
antenna disc.
Ensure not to interchange both wires. This would cause declined signal reception levels of the
WIFI and cellular network connection.
6. Exclusively BATmode 2S+:
Use the temperature sensor cable to connect the analog temperature sensor input of the
BATmode 2S+ with the corresponding temperature sensor output of the antenna disc.
7. Exclusively BATmode 2S+:
Optionally, precipitation data can be acquired by the BATmode 2S+ via the analog input or
USB/RS485 or USB/RS422 interface. For this purpose, a precipitation sensor has to be
connected to BATmode 2S+. For connecting, please refer to the manual of the precipitation
sensor.
8. To simplify the parameterization of the BATmode system peripheral pc devices (mouse,
keyboard, screens...) can be connected to the free USB and Minidisplay ports, optionally.
9. If it is intended to use wired LAN connection to remotely access the BATmode system, connect
a corresponding Ethernet cable to the LAN port (RJ45, not included in delivery) of the
BATmode.
10. Finally, connect the power supply to the BATmode.
3.2.3

When measuring at multiple measuring points with an UltraSoundGate 416Hnbm

1. Connect the USB 2.0 interface connector of the UltraSoundGate 426Hnbm with one of the
green marked UltraSoundGate ports on the front of the BATmode (see Figure 1).
2. If you utilize GM50 microphone discs, connect the XLR-input connectors of the
UltraSoundGate with the single end of the microphone cables. Subsequently, connect both
connectors at the other end of the y-wires with the microphone and reference signal speaker
Please note that microphone discs GM90 with a heating connection marked
with "5V" have to be operated only via USB heating cables and not via the
heating output of the BATmode. Violation may result in the destruction of the
microphone heater and equipment failure and damage, as well as data loss.
Only use authorized precipitation sensors und connection wires, since the use
of different devices can cause system failure, damage and loss of data.

Advertisement

Table of Contents
loading

Related Products for BAT BATmode 2S

This manual is also suitable for:

Batmode 2s+

Table of Contents