The drive unit
This mode is also used to set the start point of the rail data table by moving toward the lowest charging contact until
"rst" is visible in the display.
Exiting this mode can be done by pressing the D and I button simultaneously.
Mode -4-
The level calibration mode, used to calibrate 0⁰ level of the chair sensor and align the safety sensor.
Entering the mode will start the levelling. "0.0" I will show in the display.. This offset can be adjusted from -10⁰ to
+10⁰. Each pressing of the D button will change the value by 0.5 degree to the left and each pressing of the I button
will change the value by 0.5 degree to the right. It will start to move to the desired setting when "E" is continuously
pressed. Storing the new offset value can be done by pressing the E button for 2 seconds. The mode will then be
left.
Mode -5-
The swivel calibration mode, used to calibrate 0⁰ rotation of the chair. Changing the value is done by pressing the D
or I button. The modification has to be confirmed by pressing the E button for 2s. The mode will then be left. The
offset value can be adjusted between -10⁰ and +10⁰.
Exiting this mode can be done by pressing and holding the E button or pressing the D and I button simultaneously.
Mode -6-
The learn rail mode, in this mode the service engineer can modify the rail data. Moving the lift can only be done
when the installation joystick is connected. The following rail data can be modified:
Speed
Angle
Halt
Park
Rotation
Decreasing a value is done by the D button, increasing the value is cone by the I button.
Empty the value is done by pressing and holding the D or I button for 2s.
Confirming the value is done by pressing the E button. This will also show the next parameter to be modified
By moving the stairlift or exiting the menu by pressing the D and I button simultaneously the modified value will not
be saved.
Exiting this mode can be done by pressing and holding the E button (this will save the values) or pressing the D and I
button simultaneously.
Mode -7-
The learn RF mode, used to link control units to the stairlift.
A question mark is shown in the display (-?-) when no control units are in so called pairing mode. When the armrest
control is in pairing mode, UI is shown in the display. Any call and park unit in pairing mode will be shown as CP0 till
CP8. Selecting the number of the call and park unit is done by using the D or I buttons.
CP9 is used to identify the attendant control and shown in the display as ATT.
To confirm the link to the control unit the E button must be pressed and hold for 2s. The mode will then be left.
Exiting this mode can be done by pressing and holding the E button (this could cause a false link) or pressing the D
and I button simultaneously.
Mode -8-
Assign the call and park positions mode, used to assign the call and park unit to a defined stop position.
Three digits are shown in the display.
between 05 and 100
between -110⁰ and +110⁰
between 00 and 09
between 00 and 09
between -110⁰ and +110⁰
in steps of 5
in steps of 5
in steps of 1
in steps of 1
in steps of 5