The Transformer; Fuses; Measurement Points And Led Indications - Access Flow2A Manual

Hide thumbs Also See for Flow2A:
Table of Contents

Advertisement

The drive unit
-
+
+
Figure 4-19: Charging contacts polarity
4.3.5

The transformer

The transformer is prescribed by ThyssenKrupp:
Article number 07.72.40.100
Voltage in 220BAC 50/60Hz
Voltage out 33VDC
Power out 82.5 Watt
4.3.6

Fuses

The transformer is fitted with an automatic fuse. In case of overload the fuse ( a bi-metallic fuse) gets hot and
switches the transformer automatically. Once the transformer has cooled down it will automatically switch on again.
The control board is equipped with two resettable polyfuses. One fuse to protect the battery charging circuit and one
fuse to protect the supply for the various printed circuit boards.
The batteries are protected by a 30A fuse. This is fitted in the wiring from the battery to the control board and is not
part of the electronics.
4.3.7

Measurement points and led indications

For service purposes there are a number of test points available on the control board:
DC supplies
Battery voltage
Charger input voltage
A green led on the control board indicates that the microcontroller is alive are correct. The led will dim if the system
is in stand-by mode.
The control board is equipped with a reset button to reset the microprocessor.
-
+
37