Electrolux EOG1102COX User Manual page 5

Hide thumbs Also See for EOG1102COX:
Table of Contents

Advertisement

Available languages

Available languages

Height of the back of the
appliance
Width of the front of the ap‐
pliance
Width of the back of the
appliance
Depth of the appliance
Built in depth of the appli‐
ance
Depth with open door
Ventilation opening mini‐
mum size. Opening placed
on the bottom rear side
Ventilation opening mini‐
mum size. Opening placed
on the upper rear side
Mains supply cable length.
Cable is placed in the right
corner of the back side
Mounting screws
2.2 Electrical connection
WARNING!
Risk of fire and electric shock.
• All electrical connections should be made
by a qualified electrician.
• The appliance must be earthed.
• Make sure that the parameters on the
rating plate are compatible with the
electrical ratings of the mains power
supply.
• Always use a correctly installed
shockproof socket.
• Do not use multi-plug adapters and
extension cables.
• Make sure not to cause damage to the
mains plug and to the mains cable.
Should the mains cable need to be
replaced, this must be carried out by our
Authorised Service Centre.
• Do not let mains cables touch or come
near the appliance door or the niche
below the appliance, especially when it
operates or the door is hot.
• The shock protection of live and insulated
parts must be fastened in such a way that
it cannot be removed without tools.
576 mm
595 mm
559 mm
569 mm
548 mm
1022 mm
560x110 mm
560x50 mm
1500 mm
4x25 mm
• Connect the mains plug to the mains
socket only at the end of the installation.
Make sure that there is access to the
mains plug after the installation.
• If the mains socket is loose, do not
connect the mains plug.
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
• Use only correct isolation devices: line
protecting cut-outs, fuses (screw type
fuses removed from the holder), earth
leakage trips and contactors.
• The electrical installation must have an
isolation device which lets you disconnect
the appliance from the mains at all poles.
The isolation device must have a contact
opening width of minimum 3 mm.
• This appliance is supplied only with a
main cable.
Cable types applicable for installation or
replacement for Europe:
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total
power on the rating plate. You can also refer
to the table:
Total power (W)
maximum 1380
maximum 2300
maximum 3680
The earth cord (green / yellow cable) must be
2 cm longer than phase and neutral cables
(blue and brown cables).
2.3 Gas connection
• All gas connections must be made by a
qualified person.
• Before installation, make sure that the
local distribution conditions (nature of the
gas and gas pressure) and the adjustment
of the appliance are compatible.
• Make sure that there is air circulation
around the appliance.
• The information about the gas supply is
on the rating plate.
• This appliance is not connected to a
device, which evacuates the products of
Section of the cable
(mm²)
3 x 0.75
3 x 1
3 x 1.5
ENGLISH
5