Products
Temperature
Monitor/Limiter
Electromechanical
Panel-mounting thermostats 602021
Documentation
Declaration of conformity/White Paper
Ask for them to be sent.
CAUTION!
Failure of the device
Cutting or kinking the capillary of the device leads to permanent failure of the functions!
Physical and toxicological properties of the expansion fluid that may escape in the event of a system
fracture.
Control range
Dangerous
with end of scale
reactions
< 200 °C
No
≥ 200 °C
No
≤ 350 °C
> 350 °C
No
≤ 500 °C
NOTE!
At present, there is no restrictive statement from the health authorities concerning any danger to health
over short periods and at low concentration, e.g. after a fracture of the measuring system.
2.3

Identification marking

Depending on the version (for details see nameplate):
Fire and explosion hazard
Ignition
Explosion limit
temperature
355 °C
0.6 to 8 % v/v
490 °C
-
No
No
2 Introduction
Water
Toxicological data
contamination
Irritant
Yes
Yes
Yes
Yes
No
No
®
Danger
Toxic
to health
See note
No
See note
No
No
No