Intended Use; Identification Marking - JUMO ATH-SE Series Operating Manual

Surface-mounting thermostats
Hide thumbs Also See for ATH-SE Series:
Table of Contents

Advertisement

2.2

Intended use

The device is approved for monitoring installations on steel-hulled seagoing ships (e.g. steam and boiler
plant, indirect heating systems) as:
Temperature monitor (TW)
Safety temperature monitor STW (STB)
Safety temperature limiter (STB)
The version complies with DIN EN 14597 and is approved as per the guidelines of the Classification So-
cieties:
DNV GL
Bureau Veritas
Pressure Equipment Directive 2014/68EU (ATH.-SE-20[STW] and ATH.-SE-70[STB] only)
CAUTION!
Failure of the device
Cutting through or kinking the capillary will lead to permanent failure of the device!
NOTE!
If the measuring system breaks, the filling liquid can escape. So far, there is no restrictive health authority
statement on a health hazard in the case of short-term exposure and low concentration, e.g. in the case
of a measuring system breakage.
Note
Physical and toxic features of the expansion means, which could occur in the event of a measuring sys-
tem break.
Control range with
Hazardous
scale limit value
reactions
< 200 °C
No
≥ 200 °C
No
≤ 300 °C
a
There is currently no statement by the health authority concerning hazards to health in the event of short-term ex-
posure and low concentration, e.g. measuring system break.
2.3

Identification marking

NOTE!
The device is approved as per DIN EN 60730-2-9.
Fire and explosion hazard
Ignition
Explosion
temperature
limit
355 °C
0.6 to 8 V%
490 °C
-
Hazardous
Information about toxicology
to waters
Irritant
Yes
Yes
Yes
Yes
2 Introduction
Dangerous
Toxic
to health
a
No
a
No
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ath-se-2Ath-se-20Ath-se-70

Table of Contents