Leak Testing Procedure; Liquid Propane Gas - Cal Flame LTR20081044 Owner's Manual

Cal flame charcoal grill user manual
Table of Contents

Advertisement

Installation / Assembly
Model Number Description
BBQ08852U
Drop In Standard Side
Burner
BBQ08953U
Standard Side by Side
Burner
BBQ08954U
Deluxe Side by Side
Burner

Leak Testing Procedure

Perform a leak test at least once a year whether the gas supply has been disconnected or not. In addition, whenever
the gas supply is connected to the regulator or whenever any part of the gas system is disconnected or replaced,
perform a leak test.
As a safety precaution, remember to always leak test
your grill outdoors in a well-ventilated area. Never
smoke or permit sources of ignition in the area while
doing a leak test. Do not use a flame, such as a lighted
match to test for leaks. Use a solution of soapy water.
1.
Prepare a leak testing solution of soapy water by
mixing in a spray bottle one part liquid soap to one
part water.
2.
Make sure all the control knobs are in the OFF po-
sition.
3.
Turn on the gas. Turn the gas supply valve counter
clockwise one turn to open.
4.
Apply the leak-testing solution by spraying it on
joints of the gas delivery system. Blowing bubbles
in the soap solution indicates that a leak is pres-
ent.
5.
Stop a leak by tightening the loose joint or by re-
placing the faulty part with a replacement part rec-
ommended by the manufacturer.
6.
Turn all control knobs back to the full OFF posi-
tion.
Page 4
Width
Depth
Height
29.2 cm
45.1 cm
7.0 cm
61.6 cm
50.2 cm
10.8 cm
64.1 cm
33.7cm
18.4 cm
If you are unable to stop a leak:
1.
Turn all control knobs back to the full OFF posi-
tion.
2.
Shut off the gas supply to the grill and release
pressure in the hose and manifold by pushing in
and turning any of the control valves one quarter
turn counter-clockwise.
3.
Call an authorized gas appliance service techni-
cian.
Do not use the appliance until the leak is corrected.

Liquid Propane Gas

Tank Requirements
For plumbed-in LP installation, use a convertible regu-
lator and set it for LP gas.
Maximum line pressure for plumbed-in propane is 14"
WC (3.5 kPa). Minimum line pressure for propane is
11" WC.
Cut-out for drop in accessories
WIDTH
HEIGHT
Cal Flame 2008 Owner's Manual
LTR20081044, Rev. A
DEPTH

Advertisement

Table of Contents
loading