Leak Testing Procedure

Perform a leak test at least once a year whether the
gas supply cylinder has been disconnected or not. In
addition, whenever the gas cylinder is connected to
the regulator or whenever any part of the gas system
is disconnected or replaced, perform a leak test.
As a safety precaution, remember to always leak test
your grill outdoors in a well-ventilated area. Never
smoke or permit sources of ignition in the area while
doing a leak test. Do not use a flame, such as a
lighted match to test for leaks. Use a solution of
soapy water.
1.
Prepare a leak testing solution of soapy water by
mixing in a spray bottle one part liquid soap to
one part water.
2.
Make sure all the control knobs are in the OFF
position.
3.
Turn on the gas.
a.
On
natural gas systems, turn the main feed
valve to the grill.
b.
On
LP systems, turn the cylinder valve knob
counter clockwise one turn to open.
4.
Apply the leak-testing solution by spraying it
on joints of the gas delivery system. Blowing
7 .
Place the refrigerator in the cut-out .
Slide the refrigerator into the space in barbecue island. It is
not connected to the island in any way.
After you slide the refrigerator in its cut-out, plug it into the
outlet inside the barbecue island.
LBK-10-SW Barbecue Island
LTR50001142, Rev. A
bubbles in the soap solution indicates that a leak
is present.
5.
Stop a leak by tightening the loose joint or by
replacing the faulty part with a replacement
part recommended by the manufacturer. Do
not attempt to repair the cylinder valve if it is
damaged. The cylinder must be replaced.
6.
Turn all control knobs back to the full OFF
position.
If you are unable to stop a leak:
1.
Turn all control knobs back to the full OFF
position.
2.
Shut off the gas supply to the grill and release
pressure in the hose and manifold by pushing in
and turning any of the control valves one quarter
turn counter-clockwise.
3.
On LP systems, remove the cylinder from the
grill.
4.
Call an authorized gas appliance service technician
or an LP gas dealer.
Do not use the appliance until the leak is corrected.