General Specifications - Uwatec REBEL BC Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
⚠ WARNING
Due to heavy usage, BCs used for rental/diving centers, professional purposes or
other intensive use must be checked at least every 6 months. Overall conditions and
main safety parts such as the bladder, valves, elbow, corrugated hose, BPI must be
inspected. If any of the above parts shows wear or diminished performance it should be
replaced immediately or removed from usage, if replacement is not possible.

12. GENERAL SPECIFICATIONS

Operating temperature range
Air
-20°C
to
Water
-2°C
to
⚠ WARNING
Special Instruction in cold water diving methods, and the specific use of this product
in cold water, is required prior to cold water diving (temperatures below 10°C/50° F).
This instruction is beyond the scope of this manual.
Low pressure Hose / Pneumatic Inflation Valve
LP hose and Pneumatic Inflation Valve operating pressure
Low Pressure Hose Fitting threads
O-Rings - Seals
⚠ WARNING
This product is designed to use air or helium/nitrogen/oxygen mixtures containing
up to 40% oxygen. Use of gas mixtures with increased oxygen, or the addition of other
substances, may cause corrosion, deterioration, premature aging or component failure
of metal and rubber parts. These actions may result in loss of buoyancy control or air
holding integrity of the BC, resulting in injury or death. Non-standard gas mixtures may
also present a risk of fire or explosion.
HEIGH
WEIGHT (KG)
CUMMERBUND CIRCUMFERENCE (CM)
LIFT (N/KG)
WEIGHT (KG) WITH BPI
DISPOSAL
Finally, when the day comes when you need to replace your BC with a new SCUBAPRO BC,
dispose of the old one in accordance with local regulations and laws.
+50°C
-4°F
to
+40°C
28°F
to
122°F
104°F
95 – 200 psi (6.5 – 13.8 bar)
3/8 – 24 UNF
EPDM – Buna/Nitrile - Silicone
139 - 155
43 - 50
61 - 91
66.7 / 6.8
2
13

Advertisement

Table of Contents
loading

Table of Contents