HMS Premium BE6000 Manual Instruction page 59

Hide thumbs Also See for BE6000:
Table of Contents

Advertisement

Available languages

Available languages

Malfunction
E1
Over load in belt click
E2
Without speed signal
Short out in FET (Power
E3
Transistor)
Motor voltage is not
E4
detected
Undervoltage in main power
E5
supply
Overvoltage in main
E6
power supply
Abnormal in main power
E7
supply
Abnormal in MCU
E8
Abnormal in FET (Power
E9
Transistor)
Error in incline
E16
adjustment
Electrical failure maintenance table
Reason
3. Check up if the weight overload;
4. Check up if the running belt need to be oiled, or if the belt is
badly worn need to be replaced, or if any abnormal in driving
system (such as roller etc...)
Check up speed sensor wire well connect.
Power off for 2 minutes, then re-power. If it cannot start,
please replace the lower controller
Check up motor wire connect to controller connection is right
or not.
1. Check up spot voltage is normal or not ;
2.Check up the plug is in good connection or not.
1. Check up
not; 2. Check up the plug connection in socket loose or not.
1.
Check up
2.
Check up the plug connection in socket loose or not.
Power off for 2 minutes, then re-power. If it cannot start,
please replace the lower controller
Power off for 2 minutes, then re-power. If it cannot start,
please replace the lower controller
1. Check up the VR wire of incline is well conneted or not;
2. Re-adjust after well connecting
3. Touch the incline motor with your hand, if it is too hot , stop
to adjust the incline or cut off power for about 5 minutes, and
then re-power when the temperature returns to normal.
Treatment
the controller input power voltage is normal or
the controller input power voltage is normal or not;

Advertisement

Table of Contents
loading