Operation; Master Control - Festo ELGE-TB Operating Instructions Manual

Toothed belt axis unit

Advertisement

1. Check the mounting of the drive system.
2. Check wiring of the power supplies and the "DI/DO" digital inputs and out-
puts at the [Power] and [Logic] connections.
Procedure:
1. Switch on load voltage.
2. Switch on logic voltage (switch-on delay ≥50 ms required).
3. Wait for initialisation until C/Q LED is yellow (L 7 s).
4. Select the reference end position "Ref" from the HMI interface in the "Refer-
ence" menu and start the referencing movement with end position detection
(only required if the reference end position "Ref" is different from the factory
setting or if the useful range has been changed). The drive system is refer-
enced after successful referencing.
Referencing sets the start press position "Pos
mined useful range.
5. Parameterise operating modes via HMI interface:
Basic parameters for point-to-point operation with and without press function
or manual operation (demo)
– Velocity "Speed Out"
– Velocity "Speed In"
additional parameters for point-to-point operation with press function
– Force
– Start Press "Pos
" position (reference point end position "Ref")
Start Press
The EMCS-ST is then ready for operation and the application can be controlled via
the "DI/DO" digital inputs and outputs è 9.6 Point-to-point operating modes.
8.2
Commissioning: IO-Link operation
Preparation
1. Check the mounting of the drive system.
2. Check the wiring of the power supplies and the IO-Link "C/Q" interface at the
[Power] and [Logic] connections.
Procedure
1. Switch on load voltage.
2. Switch on logic voltage via IO-Link master (switch-on delay ≥50 ms required).
3. Wait for initialisation until C/Q LED is yellow (L 7 s).
4. Select the reference end position "Ref" from the IO-Link device data
(0x0103.0, reference) and start the referencing movement with end position
detection (0x0104.0, Execute "Reference" Movement) (only required if the
reference end position Ref" is different from the factory setting or if the useful
range has been changed). The drive system is referenced after successful
referencing.
Referencing sets the intermediate position "Pos
tion "Pos
" equal to the determined useful range.
Start Press
5. Parameterise operating modes via IO-Link interface:
Basic parameters for point-to-point operation with and without press function
or manual operation (demo)
– 0x0100.0, velocity "Speed In"
– 0x0101.0: velocity "Speed Out"
– 0x0106.0, end position "Out" "Lim
tion "Ref")
– 0x0108.0, intermediate position "Pos
position "Ref")
additional parameters for point-to-point operation with press function
– 0x0102.0, "Force"
– 0x0105.0, start press position "Pos
position "Ref")
Then the EMCS-ST is ready for operation and the application can be controlled
via the IO-Link interface "process data 0x0029.1, 0x0029.2 and 0x0029.5" or
"system parameter 0x0002" è 9.6 Point-to-point operating modes.
9

Operation

WARNING
Danger of burns from hot housing surfaces.
Metallic housing parts can reach high temperatures during operation.
Contact with metal housing parts can cause burn injuries.
• Do not touch metallic housing parts.
• After the power supply is switched off, let the device cool down to room
temperature.
9.1

Master control

– Lowest priority: DIO operation (after Power ON and initialisation)
– Medium priority: IO-Link operation (after established IO-Link communication)
– Highest priority: HMI operation (unlocked pushbuttons)
9.2
Dimension reference system
The correct positioning of the drive requires a defined dimension reference
system.
" equal to the deter-
Start Press
" and the start press posi-
Imp
" (reference point reference end posi-
Out
" (reference point reference end
Imp
" (reference point reference end
Start Press
Linear drive system
Ref
: reference end position (reference point for Lim
– motor facing (default)
– motor facing away
Lim
/Lim
: end positions
In
Out
Mech
/Mech
: mechanical stops
In
Out
Pos
: current position
Act
Pos
: intermediate position (IO-Link only)
Imp
Pos
: start press position
Start Press
Tab. 3: Dimension reference system for linear drive systems
9.3
Restart with referencing
Re-initialise reference end position "Ref"
The referencing of the reference end position is lost on Power OFF of the logic
voltage L
[Logic, Pin 1]. After every restart the position of the reference end
+
position "Ref" is re-initialised at the "Speed Ref" velocity with the first motion
task.
Referencing after a restart as a function of the positioning task
Sequence
– Mov
: force-controlled movement
Ref
– Mov
: position-controlled movement
Out
– Travel to the target position as a function of the positioning task
– No travel, end position "Lim
" reached
In
– Mov
: position-controlled movement
Out
– Mov
: position-controlled travel
Imp
Start
positioning task to the end position Lim
In
Start
positioning task to the end position Lim
Out
Start
positioning task to the intermediate position Pos
Imp
Tab. 4: Initialise restart sequence with reference end position "Ref"
, Lim
, Pos
, Pos
and Pos
In
Out
Act
Imp
Start Press
against mechanical stop "Mech
"
In
to the reference end position "Ref"
to the end position Lim
Out
to the intermediate position Lim
(IO-Link only)
Imp
In
Out
(IO-Link only)
Imp
)