Menu 3.1 Speed calibration
Menu 3.1.1 Sprayer
The calibration process is the same for each sensor type. In the fol-
lowing example a "speed sensor on sprayer" is used.
Shortcut *
1. Press * until menu [3.1.1 Sprayer] is shown.
It is possible to connect the speed sensor at different locations. See
chapter 4 - System setup for more about this. They are calibrated in
the following menus:
[3.1.1 Sprayer]
Speed sensor on sprayer
[3.1.2 Tractor]
Speed sensor on tractor
[3.1.3 Radar]
Radar speed sensor
2. Choose with the navigation keys.
3. Press # to confirm. The last confirmed sensor is the active
speed sensor.
Shortcut *
4. Press * until menu [3.1.X "Speed abc"] is shown.
5. Choose speed transducer. (Sprayer, Tractor or Radar) [3.1.1
Sprayer]
6. Press # to confirm.
7. Press # to read PPU value.
ATTENTION! Be aware that even though tractor speed sensor and radar speed sensor use the same connector, the
PPU value may be very different.
The speed transducer can be calibrated theoretically or practically.
The practical method is recommended.
7 - Menu 3 Calibration
7.1