7 - Menu 3 Calibration
5. Afterwards same procedure is repeated for opposite direction.
ATTENTION! If value has not been reached by 40 %, the display will read "Fail!". Accept this by pressing #. Then
increase hydraulic oil flow from tractor and retry calibration again.
The calibration automatically continues with gain calibration:
6. Press and hold the manual track button to the direction indicated
by the arrow in the display. Display will show a counting percentage
ending with an "OK" when gain is found.
7. Afterwards same procedure is repeated for opposite direction.
8. The display reads "CALIBRATION OK" when calibration has fin-
ished. Confirm and leave menu by pressing #.

Emergency Track

If a problem with the Track should occur, please see "Menu 4.7 Emergency Track"
7.14