Compliance; Table 2. Compliance Codes - ADTRAN HDSL 3192 HTU-C Installation And Maintenance Practice

Table of Contents

Advertisement

Compliance

The 3192 HTU-C is NRTL Listed to the applicable UL safety standards for use in continuous
environmental conditions ranging from –40°C to +50°C. Care should be exercised when
handling equipment when temperatures at these extremes exist, as surfaces could be very
cold or hot.
The 3192 HTU-C meets or exceeds all the applicable requirements of NEBS, Telcordia
GR-63-CORE and GR-1089-CORE and is evaluated to ensure proper operational performance
is maintained if environmental conditions ranging from –40°C to +65°C are encountered.
The 3192 HTU-C is intended for deployment in Central Office type facilities, EEEs, EECs, and
locations where the NEC applies (for example, customer premises). Install the 3192 HTU-C in
the appropriate chassis, which is intended to be installed only in Restricted Access Locations
by qualified personnel.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user's authority
to operate this equipment.
The compliance codes for the 3192 HTU-C are listed in
Code
Power Code (PC)
Telecommunication Code (TC)
Installation Code (IC)
Voltages up to –200 VDC with respect to ground may be present on
the HDSL telecommunications conductors. Voltages up to 200
VDC may be present between individual HDSL telecommunications
conductors.
Per GR-1089-CORE the HDSL System is designed and intended for
installation as part of a Common Bonding Network (CBN). The
HDSL System is not designed nor intended for installation as part
of an Isolated Bonding Network (IBN).
61247004L1-5A

Table 2. Compliance Codes

WARNING
CAUTION
Table
2.
Input
Output
F
C
X
A
Introduction
3

Advertisement

Table of Contents
loading

Table of Contents