Cable Gauge
Recommended maximum local loop loss information for PIC cable at 70°F, 135 Ω, resistive
termination is provided in
An approximation for the maximum amount of wideband noise on an HDSL local loop as
measured by a 50 kbps filter is ≤ 31 dBrn.
An approximation for the maximum level of impulse noise as measured using a 50 kbps filter
on an HDSL loop is ≤ 50 dBrn.
These approximations are to be used as guidelines only and may
vary slightly on different loops. Adhering to the guidelines should
produce performance in excess of 10
6

Table 3. HDSL Loss Values

(200 kHz cable loss in dB/kft at 135 Ω)
Cable Type
26
PIC
26
Pulp
24
PIC
24
Pulp
22
PIC
22
Pulp
19
PIC
19
Pulp
Table
4.

Table 4. Loop Insertion Loss Data

Frequency (Hz)
3,000
10,000
50,000
100,000
150,000
196,000
200,000
Temperature:
68°
90°
3.902
4.051
4.030
4.179
2.863
2.957
3.159
3.257
2.198
2.255
2.483
2.45
1.551
1.587
1.817
1.856
Maximum Loss (dB)
12.0
15.0
25.5
30.0
32.75
35.00
35.25
NOTE
-7
BER.
120°
4.253
4.381
3.083
3.391
2.333
2.629
1.634
1.909