Download Print this page

Illusion Aussie Made LCSII-LUMINAR Series Manual page 7

Gas log fires

Advertisement

Manufactured by Illusion Australia Pty. Ltd. 145 Sth. Gippsland Hwy Dandenong
Specifications
MODEL
GAS TYPE
Luminar LC-1000
NAT
Luminar LC-2000
NAT
Luminar LC-3000
NAT
Luminar LC-4000
NAT
NATURAL Gas Connection
The connection is made using gas pipes with Rp1/2 ISO 7 threading. Torque: 25Nm
If, alternatively, flanges are used, first screw the pipes on to the flanges and then the
flanges to the valve. Recommended torque for the flange fixing screws: 3Nm.
It is recommended that an Approved and certified shutoff valve be fitted between the incoming gas line and
the appliance to enable the gas supply to the appliance to be shut off independantly from the mains gas
supply.
Caution: After making the connections, check gas tightness.CHECK AND SET APPROPRIATE GAS PRESSURE
USING ABOVE CHART FOR NATURAL GAS ONLY
LIQUID PROPANE Gas Connection
The connection is made using gas pipes with Rp1/2 ISO 7 threading. Torque: 25Nm
If, alternatively, flanges are used, first screw the pipes on to the flanges and then the
flanges to the valve. Recommended torque for the flange fixing screws: 3Nm.
It is recommended that an Approved and Certified shutoff valve be fitted between the incoming gas line
and the appliance to enable the gas supply to the appliance to be shut off independantly from the mains gas
supply.
Caution: After making the connections, check gas tightness. CHECK GAS PRESSURE USING ABOVE CHART
FOR LIQUID PROPANE GAS ONLY.
THE FOLLOWING INDICATES SITUATIONS OF ABNORMAL OPERATION OF THE APPLIANCE.
WHEN THE APPLIANCE IS OPERATING :
1. The flames appear excessively large and / or sooting occurs on the logs.
2. You can smell gas.
3. The flame pattern is inconsistent and appears to be lifting off the burner.
4. You can smell the products of the flue within the room in which the appliance is installed. (May be an
indication of a blocked flue)
If any of the above situations occur, turn the appliance off, and contact your supplier or installer
immediately. If you can smell gas, turn the gas off at the mains and call the appropriate authority.
Always call from outside the building from a neighbors, or with a mobile phone.
Australian Made Gas Log Fires
Sth. 3175 Victoria Australia
Phone: 613 9793 7520 Fax: 613 9793 7530
The dimensions, capacities, ratings etc quoted here are correct at the time of writing but may be subject to change.
Please check with your dealer before commencing any building works or installations of these appliances.
MJH
INJECTOR
PRESSURE
SIZE
HIGH
20
2.1
.85
26
2.35
.85
32
2.6
.90
39
3.05
.75
ELECTRICAL COMPONENTS CONFORM TO AS 3100 240V 50HZ 60 WATTS
ABNORMAL OPERATION
PRESSURE
GAS TYPE
MJH
LOW
.39
LPG
16
.40
LPG
25
.47
LPG
30
.30
LPG
39
7
INJECTOR
PRESSURE
PRESSURE
SIZE
HIGH
LOW
1.3
1.8
1.6
1.6
1.8
1.6
2.0
1.7
LCSII-LUMINAR SERIES OCT 2015
1.23
1.10
0.65
0.77

Advertisement

loading