OWNERS INSTRUCTION & INSTALLATION MANUAL. PLEASE KEEP FOR FUTURE REFERENCE
ESPRIT MODELS 62-69
PYROGLOW® Gas Logs: ADVANTAGES- Realistic surface textures & colours. Radiant
natural glow of an actual fire when burning. Natural looking logs when idle. Superior strength
versus ceramic fibre.
Inert refractory formulation is ceramic fibre free. Pyroglow® logs create
virtually no fume emission. Thermal shock resistant. Contains no asbestos.
THESE APPLIANCES HAVE BEEN TESTED IN ACCORDANCE WITH AG 103 FOR
INSTALLATION AND OPERATION AS DESCRIBED IN THIS MANUAL AND HAVE BEEN
CERTIFIED BY THE AUSTRALIAN GAS ASSOCIATION.
WARNING:
All ILLUSION Gas Log Appliances MUST be installed and serviced by an authorised installer or technician.
Unauthorised installation, service or maintenance may cause a hazardous situation.
ESPRIT INBUILT MANUAL 2014

Advertisement

Table of Contents
loading

Summary of Contents for Illusion Esprit 62

  • Page 1 INSTALLATION AND OPERATION AS DESCRIBED IN THIS MANUAL AND HAVE BEEN CERTIFIED BY THE AUSTRALIAN GAS ASSOCIATION. WARNING: All ILLUSION Gas Log Appliances MUST be installed and serviced by an authorised installer or technician. Unauthorised installation, service or maintenance may cause a hazardous situation. ESPRIT INBUILT MANUAL 2014...
  • Page 2 The ILLUSION Gas Log Fire provides you with continuous warmth, and the traditional charm of a wood fired heater, without the hard work generally associated with a wood fuelled appliance. Safe and economical, you can rest easy knowing the ILLUSION Gas Log Fire has been fully tested and approved to AUSTRALIAN STANDARD AG 103.
  • Page 3 Q u a l i t y & Va l u e I n G a s L o g F i r e s EGL62NG, EGL62LP DIMENSIONS ESPRIT INBUILT MANUAL 2014...
  • Page 4 Q u a l i t y & Va l u e I n G a s L o g F i r e s EGL69NG, EGL69LP DIMENSIONS ESPRIT INBUILT MANUAL 2014...
  • Page 5 (for example, the flame failure device, limit thermostat and the like) must cut off the power supply to the thermoelectric circuit of the gas valve. Caution: After making the connections, check gas tightness. LABELLING ILLUSION GAS LOG HEATERS - MODELS EGL62NG, EGL69NG, EGL62LP AND EGL69LP Model EGL62NG EGL69NG...
  • Page 6: Lighting Instructions

    NEVER ATTEMPT TO LIGHT THE APPLIANCE IF YOU CAN SMELL GAS. IF IN DOUBT, CONTACT YOUR GAS SUPPLIER, APPLIANCE INSTALLER AND OR ILLUSION SERVICE DEPARTMENT FROM A NEIGHBOURS HOME. IF YOU CAN SMELL GAS, DO NOT USE MOBILE PHONES OR ANY ELECTRICAL APPLIANCE, OR ELECTRIC SWITCH IN THE BUILDING.
  • Page 7: Installation

    Your ILLUSION sales representative can advise on the best position to maximize the performance of the appliance. In most cases, an Authorised ILLUSION Installer can be arranged to install the unit, however if this is not possible, a suitably qualified gas fitter must be used. These appliances are not designed to be installed by the homeowner.
  • Page 8: Installation Instructions

    Q u a l i t y & Va l u e I n G a s L o g F i r e s INSTALLATION INSTRUCTIONS NOTE THAT THIS GAS APPLIANCE MAY ONLY BE INSTALLED BY AN AUTHORISED GAS FITTER. CONTACT YOUR DEALER TO ARRANGE INSTALLATION. INSTALLATION PROCEDURE INSTALLERS CHECKLIST IMPORTANT: BEFORE COMMENCING THE INSTALLATION, ESTABLISH THE OPTIMAL POSITION...
  • Page 9 Q u a l i t y & Va l u e I n G a s L o g F i r e s INSTALLATION CLEARANCES FOR INBUILT MODELS IMPORTANT: All distances shown are MINIMUM. ILLUSION Gas Log appliances UGL62NG ,UGL69NG, UGL62LP and UGL69LP must only be installed with the minimum distances shown below.
  • Page 10: Installation Option

    STANDARD CHIMNEY FLUE KIT CAN NOT BE FITTED DUE TO OBSTRUCTIONS IN THE CHIMNEY, AN APPROVED FLEXIBLE FLUE PIPE CAN BE USED. REFER TO YOU ILLUSION DEALER FOR MORE DETAILS. THE RECOMMENDED MINIMUM REFER TO INSTALLATION DISTANCE FROM THE TOP OF...
  • Page 11 Q u a l i t y & Va l u e I n G a s L o g F i r e s INSTALLATION OPTION 3 APPROVED GAS COWL TYPICAL ESPRIT INBUILT 500mm MINIMUM VERTICAL FLUE THROUGH 100mm ACTIVE FLUE PIPE WALL INSTALLATION ABOVE THE CEILING RING...
  • Page 12 Q u a l i t y & Va l u e I n G a s L o g F i r e s FITTING THE LOG SET - MODELS EGL62NG, EGL62LP FITTING THE LOGS & COALS NOTE THAT THE COALS MUST BE PLACED ONTO THE MESH SUPPORT DURING INSTALLATION OF THE LOGS AND ARRANGED SO THAT BURNER HOLES ARE NOT BLOCKED.
  • Page 13: Installation Sequence

    Q u a l i t y & Va l u e I n G a s L o g F i r e s FITTING THE LOG SET - MODELS EGL62NG, EGL62LP INSTALLATION SEQUENCE = 1-2-3-4-5-6 ADD COALS AS THE LOGS ARE NUMBERED ON THE LOGS ARE FITTED UNDERSIDE...
  • Page 14 Q u a l i t y & Va l u e I n G a s L o g F i r e s FITTING THE LOG SET - MODELS EGL69NG, EGL69LP,EGL69NG,EGL69LP FITTING THE LOGS & COALS NOTE THAT THE COALS MUST BE PLACED ONTO THE MESH SUPPORT DURING INSTALLATION OF THE LOGS AND ARRANGED SO THAT BURNER HOLES ARE NOT BLOCKED.
  • Page 15 Q u a l i t y & Va l u e I n G a s L o g F i r e s FITTING THE LOG SET - MODELS EGL69NG, EGL69LP INSTALLATION SEQUENCE = A-E-F-B-D-G-C ADD COALS AS THE LOGS ARE FITTED LOGS ARE NUMBERED ON THE UNDERSIDE...
  • Page 16: Pressure Testing

    Q u a l i t y & Va l u e I n G a s L o g F i r e s PRESSURE TESTING IMPORTANT: IF THE APPLIANCE CANNOT BE ADJUSTED TO OPERATE CORRECTLY, CONTACT YOUR SUPPLIER AND DO NOT OPERATE THE APPLIANCE UNTIL THE PROBLEM IS RECTIFIED. PRESSURE TESTING: ENSURE THE HEATER IS ISOLATED FROM THE GAS SUPPLY BY CLOSING THE MANUAL SHUTOFF VALVE DURING ANY PRESSURE TESTING.
  • Page 17 Q u a l i t y & Va l u e I n G a s L o g F i r e s INSTALLATION FLUE SPILLAGE TEST IF THE FLUE IS BLOCKED OR NOT PRODUCING SUFFICIENT DRAW, THE HEATER MUST NOT BE USED UNTIL THE PROBLEM IS RECTIFIED.
  • Page 18: Maintenance

    Replacing Logs The unit should never be used with broken logs. Always turn the gas valve off. And allow the unit to cool before opening door. Remove logs carefully.Logs should only be replaced by an Authorised ILLUSION representative. Note: Improper positioning of logs may create soot build up and carbon monoxide, which will affect heater performance.
  • Page 19 Q u a l i t y & Va l u e I n G a s L o g F i r e s ESPRIT INBUILT MANUAL 2014...
  • Page 20 Q u a l i t y & Va l u e I n G a s L o g F i r e s PARTS ASSEMBLY EXPLODED VIEW OUTER CASE TOP PANEL Spare Parts DOOR ASSEMBLY LHS BOTTOM COVER GAS VALVE ASSEMBLY BOTTOM DOOR PANEL FAN ASSEMBLY...
  • Page 21: Remote Controller Option

    Q u a l i t y & Va l u e I n G a s L o g F i r e s THERMOSTATICALLY CONTROLLED FAN Your new ILLUSION Gas Space Heater is fitted with a THERMOSTATICALLY CONTROLLED fan. EXPLANATION What this means is that other than initially setting the fan to the desired position,ie: Low High or Boost, it will no longer be necessary to turn the fan on or off whilst the unit is operating.
  • Page 22 Q u a l i t y & Va l u e I n G a s L o g F i r e s ILLUSION ESPRIT REMOTE CONTROL UNIT INSTRUCTIONS: NOTE Earlier models used the model shown below. Later versions used the remote shown on the next page.
  • Page 23: On/Off Button

    Q u a l i t y & Va l u e I n G a s L o g F i r e s OPTIONAL PROFLAME GTM REMOTE CONTROL REFER TO THE PROLAME INSTRUCTION MANUAL SUPPLIED REMOTE CONTROL-SUPPLY VOLTAGE - 4.5V (3 X 1.5 AAA BATTERIES RECEIVER SUPPLY VOLTAGE- 6.0V (4 X 1.5V AA BATTERIES) TURN OFF THE MAIN GAS SUPPLY DURING INSTALLATION OR MAINTENANCE OF THE RECEIVER.
  • Page 24: Troubleshooting

    Q u a l i t y & Va l u e I n G a s L o g F i r e s TROUBLESHOOTING •The pilot flame goes out. SYMPTOM. •First check that the gas is on, usually with another appliance such as a POSSIBLE CAUSE.
  • Page 25 Q u a l i t y & Va l u e I n G a s L o g F i r e s ILLUSION Gas Log Fires State Dealer Contact List Head Office 145 Sth Gippsland Hwy. Dandenong Sth.Victoria Australia 3175 Phone.
  • Page 26 Telephone: +61 3 9793 7520 email: service@Illusionfires.com.au www.Illusionfires.com.au Illusion Australia Pty Ltd reserves the right to alter specifications contained in this publication. Illusion Australia Pty. Ltd. admits no responsibility for printing errors or omissions within this publication. Copyright Illusion Australia Pty. Ltd. 2014 ©...