NOTE THAT THIS GAS APPLIANCE MAY ONLY BE INSTALLED BY AN AUTHORISED
PERSON. CONTACT YOUR DEALER TO ARRANGE INSTALLATION.
INSTALLATION PROCEDURE
INSTALLERS CHECKLIST
1.
IMPORTANT: BEFORE COMMENCING THE INSTALLATION, ESTABLISH THE OPTIMAL POSITION
FOR THE APPLIANCE WITH REGARD TO:
CLEARANCE FROM COMBUSTIBLE MATERIALS, POSSIBLE OBSTRUCTIONS WITHIN THE ROOF CAVITY
OR CHIMNEY, ACCESSIBILITY FOR FUTURE SERVICING, ETC:
2.
APPLIANCE & COMPONENT INSPECTION
Remove the APPLIANCE CARTON and other packaging. Inspect the appliance thoroughly to ensure it has not
been damaged in transit. Set aside the carton containing the log kit. Check to see that the correct kit is supplied.
Open the FLUE KIT carton and check to see all components are supplied including the flue lengths, outer casing,
mounting brackets & gas cowl. Ensure that the correct flue kit for your model has been supplied.
IMPORTANT:
THE MINIMUM FLUE DIMENSIONS REQUIRED FOR THESE UNITS ARE AS FOLLOWS:
MINIMUM DIAMETER OF ACTIVE FLUE ALL MODELS IS 100MM. A STAINLESS STEEL
FLUE PIPE IS USED FOR THE FIRST LENGTH OF ACTIVE FLUE PIPE. GALVANISED FLUE
PIPE IS USED FOR SUBSEQUENT LENGTHS . THE MINIMUM OVERALL HEIGHT OF THE
FLUE SYSTEM WHEN INSTALLED IS 2.7 METRES (VERTICAL FLUE EXIT MODELS) (NOT
INCLUDING GAS COWL ASSEMBLY) THE RECOMMENDED MAXIMUM FLUE HEIGHT IS
4.5 METRES (VERTICAL FLUE EXIT MODELS)
ONLY THE APPROVED GAS COWL ASSEMBLY AS TESTED WITH THE APPLIANCE MAY
BE USED WITH THESE APPLIANCES.
NOTE: These appliances are designed to be installed with a vertical flue for maximum
performance.
FLASHING (IF REQUIRED) IS NOT INCLUDED AND MUST BE SUPPLIED BY THE
INSTALLER.
3.
POSITION THE HEATER.
(ASSUMES THAT AREA IS READY FOR THE UNIT.)
Place the heater in the required position as determined in section 1 (above).
Determine where the gas supply will be accessed.
Mark the gas pipe entry point on the wall or floor, (See DIMENSIONS page 3) and cut the hole(s).
NOTE: It is highly recommended that a gas supply shut off valve be fitted to the gas inlet pipe outside the building
in an easily accessed position to enable the gas to be shut off in an emergency. This also makes it possible to keep
the gas supply connected to the rest of the home whilst fitting the pipe to the back of the heater prior to connecting
gas to the appliance.
Australian Made Gas Log Fires
INSTALLATION INSTRUCTIONS
4
LCSII-LUMINAR SERIES OCT 2015