SAI GLOBAL. WARNING: DO NOT MODIFY THIS APPLIANCE All Illusion Gas Log Appliances MUST be installed and serviced by an authorised person. Unauthorised installation, service or maintenance may cause a hazardous situation. REALISTIC GAS MANUAL APRIL 14414 DB...
The ILLusion Gas Log Fireplace provides you with continuous warmth, and the traditional charm of an open fi re, without the hard work generally associated with a wood fuelled appliance. Safe and economical, you can rest easy knowing the ILLusion Gas Log Fireplace has been fully tested and certifi ed Australian Standards.
Page 3
All dimensions for the Illusion Realistic series of Gas Log Fires are correct at the time of printing. It is always advisable to check dimensions and clearances with your Illusion dealer before commencing installation thus avoiding potential problems during the installation.
Page 4
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s Manufactured by Illusion Australia Pty. Ltd. 145 Sth. Gippsland Hwy Dandenong Sth.
- Gas Installations and any other statutory regulations.NEVER ATTEMPT TO LIGHT THE APPLIANCE IF YOU CAN SMELL GAS. IF IN DOUBT, CONTACT YOUR GAS SUPPLIER, APPLIANCE INSTALLER AND OR ILLusion SERVICE DEPARTMENT FROM A NEIGHBOURS HOME. IF YOU CAN SMELL GAS, DO NOT USE MOBILE PHONES OR ANY ELECTRICAL APPLIANCE, OR ELECTRIC SWITCH IN THE BUILDING.
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s CONTROL IDENTIFICATION FLAME CONTROL HI - LO PUSH BUTTON PIEZO IGNITER Label-for-manual.jpg...
Your ILLusion sales representative can advise on the best position to maximize the performance of the appliance. In most cases, an Authorised ILLusion Installer can be arranged to install the unit, however if this is not possible, a suitably qualifi ed gas fi tter must be used. These appliances are not designed to be installed by the homeowner.
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s INSTALLATION INSTRUCTIONS NOTE THAT THIS GAS APPLIANCE MAY ONLY BE INSTALLED BY AN AUTHORISED PERSON.
PLEASE NOTE: of 25mm, or the gap between any fl ue outer case and any timber or ALL ILLusion GAS combustible material is a minimum of LOG FIRES MUST BE 10mm. Standoffs are provided on the...
Page 10
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s INSTALLATION OPTION 2 INTO EXISTING CHIMNEY VERTICALLY APPROVED GAS COWL PLEASE NOTE: ALL ILLusion GAS LOG FIRES MUST BE INSTALLED BY AN AUTHORISED PERSON IN ACCORDANCE WITH AS/NZS 5601 - 2010...
Page 11
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s FITTING THE LOG SET - MODELS 5000-P, 5000L WARNING: DO NOT USE LOGS OTHER THAN THOSE SUPPLIED BY THE MANUFACTURER OR A HAZARDOUS SITUATION MAY RESULT.
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s PRESSURE TESTING IMPORTANT: IF THE APPLIANCE CANNOT BE ADJUSTED TO OPERATE CORRECTLY, CONTACT YOUR SUPPLIER AND DO NOT OPERATE THE APPLIANCE UNTIL THE PROBLEM IS RECTIFIED.
Page 13
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s MAINTENANCE ANNUAL SERVICE SHOULD BE PERFORMED ONLY BY AN AUTHORISED ILLusion INSTALLER OR GAS FITTER. 1) Clean the burner and control compartment of lint and house dust by brushing and Vacuuming at least once a year.
Page 14
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s PARTS ASSEMBLY EXPLODED VIEW Realistic 5000L/P Firebox body main.
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s INSTALLATION OF FASCIAS & TRIMS(FLOOR MOUNT FASCIA) The Wall mounted fascia is attached to the outer case assembly by locating the fascia bottom tabs (A) over the outer case assembly,...
Page 16
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s INSTALLATION OF FASCIAS (FLOOR MOUNT FASCIA) The Floor mount fascia is attached to the outer case assembly by locating the fascia bottom tabs (A) over the outer case assembly,...
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s THERMOSTATICALLY CONTROLLED FAN Your new ILLusion Realistic Gas Log Fire is fi tted with a THERMOSTATICALLY CONTROLLED fan.
Page 18
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s OPTIONAL PROGRAMMABLE REMOTE CONTROL ON BUTTON PRESS ONCE TO SWITCH ON.
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s TROUBLESHOOTING SYMPTOM. •The pilot fl ame goes out. POSSIBLE CAUSE.
Page 20
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s SERVICING REQUIREMENTS. “DO NOT MODIFY THIS APPLIANCE” SERVICING OF THIS APPLIANCE SHALL BE CARRIED OUT ONLY BY AUTHORISED PERSONNEL ll servicable components can be accessed via removal of the glass door assembly, and by opening the bottom door.
Page 21
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s SERVICING OF THIS APPLIANCE SHALL BE CARRIED OUT ONLY BY AUTHORISED PERSONNEL Remove logs by lifting up off the locating pins, start with the rhs bottom tier log, then the centre front bottom tier log and then the lhs bottom tier log.