Download Print this page
Illusion Aussie Made LCSII-LUMINAR Series Manual

Illusion Aussie Made LCSII-LUMINAR Series Manual

Gas log fires

Advertisement

Quick Links

HEAD OFFICE 145 SOUTH GIPPSLAND HWY DANDENONG STH. VICTORIA AUSTRALIA 3175
PH: 03 9793 7520
FAX: 03 9793 7530
Email sales@illusionfires.com.au
www.illusionfires.com.au
OWNERS INSTRUCTION & INSTALLATION MANUAL. PLEASE KEEP FOR FUTURE REFERENCE
MODELS: LCSII - LUMINAR SERIES
Your new ILLusion LUMINAR Series Gas Log Fire was designed and manufactured in Australia.
THE LUMINAR RANGE CAN BE INSTALLED IN SUITABLY CONSTRUCTED TIMBER OR METAL
ENCLOSURES OR EXISTING FIREPLACES AS PER THE MANUFACTURERS INSTRUCTIONS. PLEASE
READ AND UNDERSTAND THE INSTALLATION INSTRUCTIONS BEFORE COMMENCING TO INSTALL
THIS GAS LOG FIRE IS SUPPLIED WITH A PRIMARY GUARD FOR YOUR PROTECTION.
THE PRIMARY GUARD MUST BE FITTED WHEN THE UNIT IS OPERATING
THE GLASS FRONT OF THE APPLIANCE IS EXTREMELY HOT WHEN THE UNIT IS RUNNING AND
SEVERE BURNS MAY RESULT THROUGH CONTACT WITH THE GLASS IF THE PRIMARY GUARD IS
NOT FITTED. ADDITIONALLY A SECONDARY FIRE SCREEN MAY BE APPROPRIATE WHEN SMALL
CHILDREN OR THE INFIRM ARE IN THE VICINITY OF THE APPLIANCE.
These appliances have been tested and approved in accordance with Australian Standards
for installation and operation as described in this manual and have been Certified by IAPMO OCEANA
WARNING:
All Illusion Gas Log Appliances MUST be installed and serviced by an authorised technician.
Unauthorised installation, service or maintenance may cause a hazardous situation.
1
LCSII-LUMINAR SERIES OCT 2015

Advertisement

loading

Summary of Contents for Illusion Aussie Made LCSII-LUMINAR Series

  • Page 1 OWNERS INSTRUCTION & INSTALLATION MANUAL. PLEASE KEEP FOR FUTURE REFERENCE MODELS: LCSII - LUMINAR SERIES Your new ILLusion LUMINAR Series Gas Log Fire was designed and manufactured in Australia. THE LUMINAR RANGE CAN BE INSTALLED IN SUITABLY CONSTRUCTED TIMBER OR METAL ENCLOSURES OR EXISTING FIREPLACES AS PER THE MANUFACTURERS INSTRUCTIONS.
  • Page 2 The ILLusion Luminar Gas Log Fireplace provides you with continuous warmth, and the traditional charm of an open fire, without the hard work generally associated with a wood fuelled appliance. Safe and economical, you can rest easy knowing that every ILLusion Gas Log Fireplace has been fully tested and Australian Standards.
  • Page 3 Your ILLusion sales representative can advise on the best position to maximize the performance of the appliance. In most cases, an Authorised ILLusion Installer can be arranged to install the unit, however if this is not possible, a suitably qualified gas fitter must be used. These appliances are not designed to be installed by the homeowner.
  • Page 4 Australian Made Gas Log Fires INSTALLATION INSTRUCTIONS NOTE THAT THIS GAS APPLIANCE MAY ONLY BE INSTALLED BY AN AUTHORISED PERSON. CONTACT YOUR DEALER TO ARRANGE INSTALLATION. INSTALLATION PROCEDURE INSTALLERS CHECKLIST IMPORTANT: BEFORE COMMENCING THE INSTALLATION, ESTABLISH THE OPTIMAL POSITION FOR THE APPLIANCE WITH REGARD TO: CLEARANCE FROM COMBUSTIBLE MATERIALS, POSSIBLE OBSTRUCTIONS WITHIN THE ROOF CAVITY OR CHIMNEY, ACCESSIBILITY FOR FUTURE SERVICING, ETC: APPLIANCE &...
  • Page 5 1270mm 450mm All dimensions for the Illusion Luminar series of Gas Log Fires are correct at the time of printing. It is always advisable to check dimensions and clearances with your Illusion dealer before commencing installation thus avoiding potential problems during the installation.
  • Page 6 Example Corner Install (ALL LUMINAR Stand Alone) CURRENT EDITION All dimensions for the Illusion Luminar series of Gas Log Fires are correct at the time of printing. It is always advisable to check dimensions and clearances with your Illusion dealer before commencing installation thus avoiding potential problems during the installation.
  • Page 7 Australian Made Gas Log Fires Manufactured by Illusion Australia Pty. Ltd. 145 Sth. Gippsland Hwy Dandenong Sth. 3175 Victoria Australia Phone: 613 9793 7520 Fax: 613 9793 7530 Specifications The dimensions, capacities, ratings etc quoted here are correct at the time of writing but may be subject to change.
  • Page 8 Installations and any other statutory regulations.NEVER ATTEMPT TO LIGHT THE APPLIANCE IF YOU CAN SMELL GAS. IF IN DOUBT, CONTACT YOUR GAS SUPPLIER, APPLIANCE INSTALLER AND OR ILLusion SERVICE DEPARTMENT FROM A NEIGHBOURS HOME. IF YOU CAN SMELL GAS, DO NOT USE MOBILE PHONES OR ANY ELECTRICAL APPLIANCE, OR ELECTRIC SWITCH IN THE BUILDING.
  • Page 9 Australian Made Gas Log Fires CONTROL IDENTIFICATION REMOTE PUSH BUTTON FLAME CONTROL CONTROL SWITCH PIEZO IGNITER HI - LO MODEL 1000 - HIGH 1000 - TURNDOWN GAS TYPE LPGL 16Mjh 10.9Mjh NOM. HOURLY GAS CONSUMPTION 1.80kPa .77kPa MANIFOLD PRESSURE 1.3mm INJECTOR SIZE LUMINAR 1000 LABEL.pdf 1 9/11/2015 9:39:12 AM To replace batteries in remote receiver,...
  • Page 10 Only persons familiar with the operation of the unit should use the heater. Do not modify or adjust the heater. Always contact your ILLusion dealer if any problems arise. Annual service by an Authorised service person will ensure trouble free operation for many years.
  • Page 11 MAY RESULT. BROKEN OR DAMAGED LOGS OR PEBBLES MUST BE REPLACED WITH THE CORRECT PART. CONTACT YOUR NEAREST ILLUSION DEALER FOR MORE INFORMATION. Fit the logs as shown in the photos below. Always start at the rear, then the middle, then the front. The logs have holes to correspond with the pins near the burners.
  • Page 12 Australian Made Gas Log Fires FITTING INSTRUCTIONS FOR LOGS (CONT.) Luminar 3000 Empty firebox with door removed Fit the large rear number 1 log first. Fit the number 2 log next on the lhs ready to fit the logs. of the middle row Next fit the number 3 log to the rhs Now fit the number 4 log to the lhs Finally, fit the number 5 log on the...
  • Page 13 Australian Made Gas Log Fires FITTING THE PEBBLES - LUMINAR There a 3 types of Pebbles supplied, SMALL ROUND, LARGE OVAL, LARGE IRREGULAR. (See Images) WARNING: DO NOT USE PEBBLES OTHER THAN THOSE SUPPLIED BY THE MANUFACTURER OR A HAZARDOUS SITUATION MAY RESULT. WHEN INSTALLING PEBBLES, ENSURE THAT THE BURNER HOLES ARE NOT OBSTRUCTED.
  • Page 14 Australian Made Gas Log Fires PRESSURE TESTING IMPORTANT: IF THE APPLIANCE CANNOT BE ADJUSTED TO OPERATE CORRECTLY, CONTACT YOUR SUPPLIER AND DO NOT OPERATE THE APPLIANCE UNTIL THE PROBLEM IS RECTIFIED. PRESSURE TESTING: ENSURE THE HEATER IS ISOLATED FROM THE GAS SUPPLY BY CLOSING THE MANUAL SHUTOFF VALVE DURING ANY PRESSURE TESTING.
  • Page 15 Australian Made Gas Log Fires MAINTENANCE ANNUAL SERVICE SHOULD BE PERFORMED ONLY BY AN AUTHORISED ILLusion INSTALLER OR GAS FITTER. 1) Clean the burner and control compartment of lint and house dust by brushing and Vacuuming at least once a year.
  • Page 16 Australian Made Gas Log Fires THERMOSTATICALLY CONTROLLED FAN Your new Gas Log Fire is fitted with a THERMOSTATICALLY CONTROLLED fan. EXPLANATION What this means is that other than initially setting the fan to the desired position,ie: Low or High, it will no longer be necessary to turn the fan on or off whilst the unit is operating.
  • Page 17 Australian Made Gas Log Fires OPTIONAL PROFLAME GTM REMOTE CONTROL REFER TO THE PROLAME INSTRUCTION MANUAL SUPPLIED REMOTE CONTROL-SUPPLY VOLTAGE - 4.5V (3 X 1.5 AAA BATTERIES RECEIVER SUPPLY VOLTAGE- 6.0V (4 X 1.5V AA BATTERIES) TURN OFF THE MAIN GAS SUPPLY DURING INSTALLATION OR MAINTENANCE OF THE RECEIVER. ON/OFF BUTTON THERMOSTAT KEY UP/DOWN ARROW KEY...
  • Page 18 Australian Made Gas Log Fires TROUBLESHOOTING SYMPTOM. •The pilot flame goes out. POSSIBLE CAUSE. •First check that the gas is on, usually with another appliance such as a gas stove. •The pilot sensor (Thermocouple) may be faulty. SOLUTION. • Contact your Dealer. SYMPTOM.
  • Page 19 Australian Made Gas Log Fires LCSII-LUMINAR SERIES OCT 2015...
  • Page 20 Telephone: +61 3 9793 7520 Fax: +61 3 9793 6816 email: service@Illusionfires.com.au www.Illusionfires.com.au Illusion Australia Pty Ltd reserves the right to alter specifications contained in this publication. Illusion Australia Pty. Ltd. admits no responsibility for printing errors or omissions within this publication. Copyright Illusion Australia Pty. Ltd. 2015 ©...