Download Print this page
Illusion Mystique 8000L Owner's Instructions & Installation Manual

Illusion Mystique 8000L Owner's Instructions & Installation Manual

Gas log fires

Advertisement

Quick Links

HEAD OFFICE 145 SOUTH GIPPSLAND HWY DANDENONG STH. VICTORIA AUSTRALIA 3175
PH: 03 9793 7520
FAX: 03 9793 7530
Email sales@illusionfires.com.au
www.illusionfires.com.au
OWNERS INSTRUCTION & INSTALLATION MANUAL. PLEASE KEEP FOR FUTURE REFERENCE
MODEL: Mystique 8000L Gas Log Fires
Your new ILLusion Gas Log Fire was designed and manufactured in Australia.
THE ILLUSION MYSTIQUE CAN ONLY BE INSTALLED IN A SUITABLY
CONSTRUCTED TIMBER OR METAL ENCLOSURE AS PER THE MANUFACTURERS
INSTRUCTIONS. IT IS NOT SUITABLE FOR EXISTING CHIMNEYS
These appliances have been tested and approved in accordance with Australian Standards
for installation and operation as described in this manual and have been
certified by the Australian Gas Association.
WARNING:
All Illusion Gas Log Appliances MUST be installed and serviced by an authorised technician.
Unauthorised installation, service or maintenance may cause a hazardous situation.
MYSTIQUE MANUAL JULY 2014

Advertisement

loading

Summary of Contents for Illusion Mystique 8000L

  • Page 1 Australian Gas Association. WARNING: All Illusion Gas Log Appliances MUST be installed and serviced by an authorised technician. Unauthorised installation, service or maintenance may cause a hazardous situation. MYSTIQUE MANUAL JULY 2014...
  • Page 2 The ILLusion Gas Log Fireplace provides you with continuous warmth, and the traditional charm of an open fire, without the hard work generally associated with a wood fuelled appliance. Safe and economical, you can rest easy knowing the ILLusion Gas Log Fireplace has been fully tested and approved Australian Standards.
  • Page 3 THE FRAME ! All dimensions for the Illusion Mystique series of Gas Log Fires are correct at the time of printing. It is always advisable to check dimensions and clearances with your Illusion dealer before commencing installation thus avoiding potential problems during the installation.
  • Page 4 I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s INSTALLATION IN A PURPOSE BUILT FACADE IMPORTANT! DO NOT FIT THE PLASTER UNTIL THE HEATER HAS BEEN INSTALLED INTO THE FRAME!
  • Page 5 I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s Manufactured by Illusion Australia Pty. Ltd. 145 Sth. Gippsland Hwy Dandenong Sth.
  • Page 6 Installations and any other statutory regulations.NEVER ATTEMPT TO LIGHT THE APPLIANCE IF YOU CAN SMELL GAS. IF IN DOUBT, CONTACT YOUR GAS SUPPLIER, APPLIANCE INSTALLER AND OR ILLusion SERVICE DEPARTMENT FROM A NEIGHBOURS HOME. IF YOU CAN SMELL GAS, DO NOT USE MOBILE PHONES OR ANY ELECTRICAL APPLIANCE, OR ELECTRIC SWITCH IN THE BUILDING.
  • Page 7 SPECIFICATIONS SWITCH PRIMARY GUARD THE Mystique 8000L GAS LOG FIRE IS SUPPLIED WITH A PRIMARY GUARD FOR YOUR PROTECTION. THE PRIMARY GUARD MUST BE FITTED WHEN THE UNIT IS OPERATING THE GLASS FRONT OF THE APPLIANCE IS EXTREMELY HOT WHEN THE UNIT IS RUNNING AND SEVERE BURNS MAY RESULT THROUGH CONTACT WITH THE GLASS IF THE PRIMARY GUARD IS NOT FITTED.
  • Page 8 Your ILLusion sales representative can advise on the best position to maximize the performance of the appliance. In most cases, an Authorised ILLusion Installer can be arranged to install the unit, however if this is not possible, a suitably qualified gas fitter must be used. These appliances are not designed to be installed by the homeowner.
  • Page 9 ONLY THE APPROVED GAS COWL ASSEMBLY AS TESTED WITH THE APPLIANCE MAY BE USED WITH THESE APPLIANCES. NOTE: The Mystique 8000L is designed to be installed with a vertical flue only for maximum performance. FLASHING (IF REQUIRED) IS NOT INCLUDED AND MUST BE SUPPLIED BY THE INSTALLER.
  • Page 10 I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s INSTALLATION INTO FABRICATED ENCLOSURE VERTICALLY ONLY PLEASE NOTE: ALL ILLusion GAS LOG FIRES MUST BE INSTALLED BY AN AUTHORISED PERSON...
  • Page 11 I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s INSTALLATION INTO FABRICATED ENCLOSURE VERTICALLY ONLY IMPORTANT INSTALLATION INFORMATION THE ABOVE CLOSE UP DETAILS HOW THE APPLIANCE SITS BELOW THE BOTTOM PLASTER LIP.
  • Page 12 I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s FITTING THE LOG SET - MODEL 8000L WARNING: DO NOT USE LOGS OTHER THAN THOSE SUPPLIED BY THE MANUFACTURER OR A HAZARDOUS SITUATION MAY RESULT.
  • Page 13 I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s PRESSURE TESTING IMPORTANT: IF THE APPLIANCE CANNOT BE ADJUSTED TO OPERATE CORRECTLY, CONTACT YOUR SUPPLIER AND DO NOT OPERATE THE APPLIANCE UNTIL THE PROBLEM IS RECTIFIED.
  • Page 14 I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s MAINTENANCE ANNUAL SERVICE SHOULD BE PERFORMED ONLY BY AN AUTHORISED ILLusion INSTALLER OR GAS FITTER. 1) Clean the burner and control compartment of lint and house dust by brushing and Vacuuming at least once a year.
  • Page 15 I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s PARTS ASSEMBLY EXPLODED VIEW Mystique 8000L Firebox body main.
  • Page 16 I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s INSTALLATION OF FASCIAS & TRIMS The Wall mounted fascia is attached to the outer case assembly by locating the fascia tabs (A) into the slots on the outer case assembly (B) , as shown below.
  • Page 17 I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s THERMOSTATICALLY CONTROLLED FAN Your new ILLusion Mystique 8000L Gas Log Fire is fitted with a THERMOSTATICALLY CONTROLLED fan.
  • Page 18 I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s OPTIONAL PROFLAME GTM REMOTE CONTROL REFER TO THE PROLAME INSTRUCTION MANUAL SUPPLIED REMOTE CONTROL-SUPPLY VOLTAGE - 4.5V (3 X 1.5 AAA BATTERIES RECEIVER SUPPLY VOLTAGE- 6.0V (4 X 1.5V AA BATTERIES) TURN OFF THE MAIN GAS SUPPLY DURING INSTALLATION OR MAINTENANCE OF THE RECEIVER.
  • Page 19 I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s TROUBLESHOOTING •The pilot flame goes out. SYMPTOM.
  • Page 20 Telephone: +61 3 9793 7520 Fax: +61 3 9793 6816 email: service@Illusionfires.com.au www.Illusionfires.com.au Illusion Australia Pty Ltd reserves the right to alter specifications contained in this publication. Illusion Australia Pty. Ltd. admits no responsibility for printing errors or omissions within this publication. Copyright Illusion Australia Pty. Ltd. 2014 ©...

This manual is also suitable for:

Mystique-5000lMystique-5000ng