Stand Alone Clearances
The diagrams below show examples of stand alone Luminar installs
with respect to clearances from combustible materials ie: walls. The
minimum distance from the REAR of all Luminar Stand Alone models
to any combustible surface is 10mm. The minimum distance from the
SIDES of all Luminar Stand Alone models is 100mm.
The minimum distance from the REAR CORNERS to combustible walls
in a 45 degree corner install is 10mm.
50mm REAR WALL (ALL LUMINAR Stand Alone)
50mm
(Min.)
Example Corner Install (ALL LUMINAR Stand Alone)
All dimensions for the Illusion Luminar series of Gas Log Fires are correct at the time of printing. It is always
advisable to check dimensions and clearances with your Illusion dealer before commencing installation
thus avoiding potential problems during the installation.
IMPORTANT NOTE TO INSTALLER
Caution:
Check the appliance before leaving.
Check that logs or pebbles are correctly located. Incorrect location of logs or pebbles
will affect combustion and may cause sooting.
Check the gas pressure.
Light the appliance and check for flame abnormalities on both high and low flame
settings. Flames should not lift off the burner ports. Allow the unit about 5 minutes to
warm up then if the flames are lifting from the burner ports it may be necessary to
adjust the gas pressure on the gas valve.
Australian Made Gas Log Fires
LUMINAR STAND ALONE INSTALLATION
(C)
(A)
50mm
50mm
(Min.)
The Illusion Luminar STAND ALONE Gas Log Fires have been designed
for simple installation with the approved balanced flue provided. The
miniumum
flue height is 2.7m, the maximum recommended flue height is 4.5m Most
installations will use the standard flue height of 3.6m
Illusion Luminar gas log fires must only be installed by an authorised
gasfitter.
TYPICAL FLUE INSTALLATION
Minimum
500mm
from flue cowl
exit to roof
penetration
Minimum
distance
from flue
Flue Pipe
case outer
100mm
pipe to
(4")
combustible
Active &
materials is
152mm
10mm
(6")
Outer
Minimum
distance
from top of
unit to any
combustible
framing is
50mm
Appliance
Fascia
6
Approved
Vertical
Flue Cowl
Flashing
(Supplied
by
Installer)
Minimum
distance
from
combustible
rear wall to
the back of
the unit is
10mm
Vertical
Flue
LUMINAR
ALL LUMINAR GAS
Gas Log
LOG FIRES MUST BE
INSTALLED IN
Fire
ACCORDANCE WITH
AS-NZS 5601
CURRENT EDITION
LCSII-LUMINAR SERIES OCT 2015