6. INSTALLATION OPTIONS:

6.1 General:

For the BTP pumps the following installations are possible:
-
Installation -H
-
Installation -R
-
Installation -V
-
Installation -K

6.2 Installation - H:

Horizontal installation on base plate.
Checkpoints before operation:

6.2.1 Alignment of pump and motor shaft:

After the base-plate is fixed to the floor, the alignment of pump and motor-shaft must be checked.
When the base-plate is fixed to the floor, forces on the base-plate might have disturbed the
alignment .
To improve the alignment, use skims underneath the motor and pump fixing bolts.
Re-install the protection hood in the original position.
Landustrie version 06-14 | Operation & Maintenance manual BTP-SERIES
Subject to modifications
Horizontal, on base plate
Horizontal, on rail construction
Vertical, on support
V-belt driven
The main parts are:
1.
2.
3.
4.
5.
6.
7.
8.
9.
- Fixation of the base-plate to the floor.
- Flanges straight horizontal and vertical
see fig. pos 1.
- Pump and motor shaft aligned,
see 6.2.1.
- Maximum flange forces and moments,
see 6.5.
- Adjust start and stop levels in such a way
that the pump does not make more than 20
starts per hour.
- Remove the protection hood, (pos 4).
- Check for:
- 1 radial deflection (R) max. 0.4mm.
- 2 angular deflection (A) max. 1
pump unit;
bearing unit;
flexible spacer coupling;
protection hood
electric motor;
base plate;
fixing bolts;
delivery pipe;
suction pipe;
o
9 / 28