3.4 Sound level:

Depending on duty point and speed, the pump will produce a certain sound level.
Next to this the piping system may produce some noise and vibration.
By altering the pipe support and using rubber compensators the vibration will be reduced.
In the next table the sound levels of the BTP pumps are shown.

4. CHECK POINTS BEFORE INSTALLATION:

After unpacking the pump, follow out the following check points:

4.1 Delivery-check:

Check for possible transport damage.
Check for complete delivery.
When the delivery is incomplete or damaged, please contact your dealer immediately.

4.2 Oil level:

Check the oil level in the oil tank.
The oil plug has a gauge rod and the level should be between the two indications.

4.3 Power supply:

Before making the electrical connections, check if the line voltage and frequency are
the same as on the pump data-plate.
If thermostats are supplied make sure that they are correctly connected.
For examples of electrical diagrams and pump cable coding, see appendix 1 and 2.
Landustrie version 06-14 | Operation & Maintenance manual BTP-SERIES
Subject to modifications
Sound levels BTP pumps
Type
Speed
[rpm]
BTP62-40
960/1450
BTP62-50
960/1450
Sound level
[dB]
<70
<70
6 / 28