Starting up:

Rotation control:
Minimum water level:
The pump should operate with sufficient cooling.
This means that at least ⅔ of the motor is submerged.
Reducing this minimum level means the motor runtime is limited to a maximum of 15 minutes, to
avoid overheating. The cooling down time is at least twice the running time.

Electrical pump start options:

The different connections for the cables are specified on page 8 and 9.
Check the cable type, installed on the pump and verify the data onto the pump data plate.
Check if the pump is equipped with extra leads for thermal protection and/or water in oil
detection.
We do strongly recommend to connect the pump to the mains by authorized personal only.
Please ensure this is done accordingly and in compliance with local regulations.
Landustrie versie 01-21 | Operation & maintenance manual DCP22
Subject to modifications
The correct direction of rotation is counter clockwise
(ccw), looking at the suction opening of the pump (see
picture).
Check procedure:
Place the pump into horizontal position, start the pump short time,
check visually the direction of rotation,
Please follow all safety measures!.
The correct direction of rotation can also be checked by observing
the recoil of the pump during start up.
Looking at the motor the recoil should be counter clockwise (ccw)