7.6.7 Renewal Flexible coupling installation –V and RF:
- Remove the protective caps from the lantern housing
and remove the print caps (2) and the rubber
element.
- Remove the electric motor from the lantern house.
- Remove the setscrews from the hubs.
- The old clutch parts can now be
removed using a correct trigger.
- Pay attention to the current position on the axis!
- Mount the hub parts (1) on both the motor shaft and
the pump shaft.
- Think about the correct positioning!
- Place the electric motor back on the lantern housing.
- Check that the distance (S) is between 204 mm and tighten set screws.
- Check whether the coupling parts are aligned.
- Fit the new rubber element (3) and fit the cover caps (2).
- After this, replace the protective caps of the lantern housing.
The pump is now ready for operation again at this point.