6.6 Maximum flange forces and moments:
Because of the pipeline system, specific forces on the discharge and suction flanges will occur.
The forces and moments may not exceed the values stated in the table below:
Fx
Fy
Pump
type
[N]
[N]
BTP62-40 1400
1400
BTP62-50 1400
1400
Landustrie version 06-14 | Operation & Maintenance manual BTP-SERIES
Subject to modifications
This forces consists of two factors
1. Forces Fx, Fy and Fz
2. Moments Mxy, Mxz and Myz
Fz
Mxy
Mxz
Myz
[Nm]
[N]
[Nm]
[Nm]
3000
1200
1200
1300
3000
1200
1200
1300
13 / 28