In this interface, you can also do the following:
To simulate hardware signal, press F1 to conduct a simulation test or F2 to
close a simulation test.
The sign T shows next to the port, which means the port is under test.
To cancel all simulation tests and signals, press F3.
To set the filter time, press F5.
The system rules out interference signals whose occurrence time is shorter
than the set filter time.
To monitor the target port, press F6.
The system adds the port to the diagnosis list in Diagnosis interface.
To display all I/O ports, including ports not used and defined, press F7.
You can press F7 again to hide them again.
To share port Reference Point, Positive Limit and Negative Limit, press
→ F2.
Ports with the same port address share a port.

2.3 Set Commissioning Parameters

This operation is used to set parameters for commissioning, to avoid damage to the
machine tool during its movement.
According to the type of control system, it can be divided into the following:
Set commissioning parameters for bus control system.
Set commissioning parameters for non-bus control system.
To set the type of control system, press
manufacturer password, and modify the value of parameter N50000 Control
System Type.
2.3.1 Set Commissioning Parameters for Bus Control System
Before setting commissioning parameters for bus control system, ensure the
following:
Parameter N50000 Control System Type is set to 1.
The used terminal board is Lambda 5M.