What is Remote Reset? 
 
Remote  Reset  allows  you  to  remotely  trigger  a  reset  of  the  Totalization  on  your  Digital        
Electronics.  This feature is similar to pressing the RESET Button from the TOP.RUN page.  The 
Remote  Reset  can  be  utilized  by  installing  a  remote  push  button  on/off  switch  (customer    
supplied).    To  properly  wire  the  push  button  on/off  switch  for  Remote  Reset  Capabilities, 
please see the Wiring Customer Connections section of Chapter 1. 
 
When to Perform Zero 
 
Zeroing should be performed after initial installation and after any mechanical procedures or 
replacement of parts, such as Loadcells or Measurement Pans.  Once properly calibrated, the 
meter may be zeroed periodically if deemed necessary.  Recommendations of whether to zero 
the meter or not and how often to zero the meter are application specific.  Typically, zeroing is 
recommended  in  the  case  that  zero  drift  contributes  sufficient  error  to  prevent  the  desired 
accuracy.  Zero drift may occur due to product buildup on the pan, temperature changes, and 
other factors.  Generally, this is not a problem since the user may zero the meter in order to 
remove the offset before the reintroduction of product flow through the meter. 
 
Enabling the Remote Reset Capability 
 
Once  the  switch  is  wired  properly,  you 
must  enable  the  Remote  Reset.  To        
enable  the  Remote  Reset  Capability,     
access the I/O Menu from the TOP.MENU 
page  and  click  on  the  REMOTE  RESET  
Button.  You  should  now  see  the  page 
shown  to  the  right.    To  enable  Remote 
Reset, simply press the ENABLE BUTTON.  
If  enabled,  the  word  "Yes"  will  be          
displayed to the right of the button.   
 
Selecting Remote Reset, Zero or Both 
 
Pressing the TYPE Button will allow you to 
choose  the  function  of  pressing  your  Re‐
mote Push Button.  It will either function 
as a Remote Reset, to Zero the meter, or can function as both simultaneously. 
 
 
Logic 
 
The  logic  of  the  Remote  Reset  Capability  can  also  be  manipulated.    If  the  LOGIC  Button  is 
pressed, a dialog box will prompt you to chose from two options, "NC" or "NO".  The option 
"NC" is Normally Closed, while "NO" is Normally Open. 