Step 6:
You
I/O.RATE.SP page. The Rate
Target Button is highlighted in
Yellow. You can change the Rate
Target by pressing the current
Rate Target value twice. The first
press will outline the value in
black, as shown. The second press
will b ring up a numeric keypad and
the Target Rate can be changed.
The maximum value that can be
used is Full Scale, which is
displayed in a dark Blue highlight.
Step 7:
Now return to the I/O.ALARM page. Make sure that the blue display box to the
right of the LOGIC Button says Positive. If it does not, press the LOGIC Button until
it does. Details on the LOGIC Button can be found in the HMI Screen Guide for the
I/O ALARM PAGE.
Step 8:
Return to the I/O.ALARM page once more. To turn the alarm on, press the ENABLE
Button until "YES" is displayed in the blue display box to the right of the ENABLE
Button.