Step 3: After product has stopped flowing through the meter, go to the SET.FIELD page
located under the SET option on the MAIN MENU. HINT: Press the MENU softkey,
then press SET, and finally, FIELD DATA.
Step 4: Click on the "ENTER RUN" Button and you should see the GREEN value (CF Meter)
change from "0.000" to a number signifying the weight that the electronics calculates
passed through the meter.
Step 5: Weigh the collected material on a static scale and record the weight in the YELLOW
block (Actual) next to the value automatically entered in STEP 4. Press the YELLOW
box to bring up a numeric keypad. After entering the value, press the NEXT RUN
Button to prepare for the next run. It is important that the container holding the
material not be included in the weight. The only weight that is important is the
material that actually went through the meter.
Step 6: Return to the TOP.RUN page and press the RED RESET Button on the bottom left.
Step 7: Repeat Steps 2‐6 four more times to complete the 5 Field Data runs.
Step 8: Once all five runs are completed click on the RUN Number next to each set of data in
order to select each data RUN. When selected the circles next to the numbers will
become green as seen in the picture above.