Process Values; Logger Data - ABB AquaMaster4 Operating Instruction

Electromagnetic flowmeter transmitter
Hide thumbs Also See for AquaMaster4:
Table of Contents

Advertisement

A Q U A M A S T E R 4 | E L E C T R O M A G N E T I C F LO W M E T E R T R A N S M I T T E R | O I/ F E T4 0 0 - E N R E V. D

Process values

This window displays operating values for the selected
flowmeter:
Aqm4
ID:4294967295
Last access: 10/05/2021 16:35:18
Flow Measurements
Flow rate
28.789
l/s
Velocity
3.411
m/s
Volume Totalizers
Forward Volume
1,008.0106
m3
Reverse Velocity
0.0000
m3
Net Volume
1,008.0106
m3
Pressure Measurements
Pressure
1.000
Bar
Digital Outputs
?
Process Values
Configurtion
Figure 73 Process Values window
LOGGER
LOGGER
LOGGER
i
Diagnostics

Logger data

If the (optional) logger functionality was ordered, logger data is
acquired by pressing the LOGGER button when the Process
Values window is displayed. The log type and a date/time range
must be specified.
Data acquisition is started by pressing the GET LOGGER DATA
button and holding the phone or tablet within NFC range of the
associated transmitter.
Logger menu options comprise:
Menu
Function
Get ... Log
A drop-down menu used to select
one of the following log types:
Get Flow and Pressure Log
Get Flow Log
Get Pressure Log (pressure transducer option required)
Get Totalizer Log
Date (from)
A user-set calendar used to enter the date to start logging
Date (to)
A user-set calendar used to enter the date to cease logging
Time (from)
A user-set clock used to enter the time to start logging
Time (to)
A user-set calendar used to enter the time to cease logging
Acquired data is displayed on a chart (see below) and can be
shared via Bluetooth/email or saved to a drive – see page 48:
Logger
Get Flow Log
01/06/2017
16:12
GET LOGGER DATA
300
250
200
150
100
50
Flow [m3/day]
Rotate device for larger view
Figure 74 Example of logger data displayed on a chart
13/06/2017
16:12
49