Section 5 Final Checks

Section 5 Final Checks
Do not use the F3SP until the following inspections are completed. Failure to do so
may result in loss of life or serious injury.
A qualified person, as determined by local regulations, must confirm that
installation and inspection are implemented correctly.
Check that the area protected by the light curtain is free from any obstacle; check the
correct triggering of the output contacts opening by interrupting the protection rays
(OUTPUT indicator red is lit, controlled machine stopped).
If the OUTPUT indicator red LED switches on and off, check the correct mechanical
installation.
[Note]: This check must be repeated each time you move or mechanically re-
align the light curtains and muting sensors.