Section 1 Description

1-2 Functions

1-2-1 Interlock function

The auto reset mode and the manual reset mode are selectable features of the F3SP.
The selection will be done by dip switch (Please refer to Section 4-1 for selection of dip
switch).
[Note]: While the F3SP is connected to power, do not change any dip switch to
1) Auto reset mode
The F3SP automatically starts after power-ON and automatically restarts after the
object in the detection zone is removed.
2) Manual reset mode
Returns to the normal operating mode only after the object has been removed and the
RESET button has been pressed.

1-2-2 Test function

1) Self-test
After power ON, the F3SP performs a complete self-test. In addition, it performs a self-
test periodically during operation.
2) External test
This is used to check if the whole system works effectively. By pressing the TEST
(NOTE1)
button
, this simulates the interruption of one or both safety light curtains. This
operation makes the machine stop, so the system checks can be made according to
the established time and modes.
[Note1]: TEST button must be pressed more than 100ms.
3) Error detection and restoration (Lockout condition)
If an error is detected by the self-test the F3SP enters the lockout condition, keeps the
in their OFF-state and displays the error code
Turning the power ON again, or applying the pressing RESET button, resets the
lockout condition.
*1. Refer to Section 7 Status indication codes for the indicating patterns.
2
avoid influence on the system safety.
(*1)
in status indicator.