Advertisement

Quick Links

Series FR597G Ortho-Biotic
II Recliner
with Wooden Arm Caps
Series FR597P Ortho-Biotic
II Recliner
with Fully Upholstered Arms
Series FR597GH Ortho-Biotic
II Recliner
with Wooden Arm Caps with Heat and Massage
Series FR597PH Ortho-Biotic
II Recliner
with Fully Upholstered Arms with Heat and Massage
Series FR597GHO Ortho-Biotic
II Recliner
with Wooden Arm Caps with Heat Only
Series FR597PHO Ortho-Biotic
II Recliner
with Fully Upholstered Arms with Heat Only
Series FR597G Shown
Assembly and Operating Instructions
SAVE THIS MANUAL FOR FUTURE USE.
LX_FR597-INS-LAB-RevE21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LUMEN Ortho-Biotic II FR597G Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Graham Field LUMEN Ortho-Biotic II FR597G Series

  • Page 1 Series FR597G Ortho-Biotic II Recliner ™ with Wooden Arm Caps Series FR597P Ortho-Biotic II Recliner ™ with Fully Upholstered Arms Series FR597GH Ortho-Biotic II Recliner ™ with Wooden Arm Caps with Heat and Massage Series FR597PH Ortho-Biotic II Recliner ™ with Fully Upholstered Arms with Heat and Massage Series FR597GHO Ortho-Biotic II Recliner...
  • Page 2: Table Of Contents

    CONTENTS INTRODUCTION ..................................3 INTENDED USE ................................3 IMPORTANT SAFETY PRECAUTIONS—READ BEFORE USE ...................3 WARNINGS ................................3 UNPACKING AND ASSEMBLY .............................5 PACKAGING ...................................5 UNPACKING THE RECLINER ............................5 SERIES FR597 ORTHO-BIOTIC II RECLINER DESCRIPTION AND FEATURES ..............6 OPERATION ..................................7 TENTE CASTERS................................7 ® RECLINER OPERATION..............................7 LEGREST OPERATION ..............................8 EXTENDING LEGREST ............................8 RETURNING LEGREST TO STORED POSITION ....................8...
  • Page 3: Introduction

    INTRODUCTION This manual contains assembly, operation, and maintenance instructions for Lumex Ortho-Biotic II Recliners series FR597G (FR597G, FR597GH, and FR597GHO) and FR597P (FR597P, FR597PH, and FR597PHO). Read the entire manual carefully before using your recliner, and refer to it during use if you have questions.
  • Page 4 WARNING: Unauthorized modification of your recliner or the use of non-Lumex replacement parts may change the structure of the recliner and could create a hazardous condition, which may result in serious injury and will void the warranty. WARNING: This product can expose you to chemicals including Di(2-ethylhexyl)phthalate (DEHP) which is known to the State of California to cause cancer and birth defects or other reproductive harm.
  • Page 5: Unpacking And Assembly

    UNPACKING AND ASSEMBLY 1. The Lumex Ortho-Biotic II Recliner is delivered in a three-piece single shipping carton strapped to a pallet. Upon delivery, ensure all cartons are present. Note any shortages on the delivery receipt. 2. Check for any obvious damage to the carton or contents. If damage is evident, immediately notify the carrier, your GF authorized distributor, and / or GF Health Products, Inc.
  • Page 6: Series Fr597 Ortho-Biotic Ii Recliner Description And Features

    SERIES FR597 ORTHO-BIOTIC II RECLINER DESCRIPTION AND FEATURES Adjustable Padded Universal Headrest Push Handle Legrest-Recline Adjustment Lever Total Locking Directional Locking Caster (3) Caster (1) Pull-Out Footplate Trendelenburg Foot Pedal (RIGHT SIDE ONLY) Series FR597G Shown LX_FR597-INS-LAB-RevE21...
  • Page 7: Operation

    OPERATION TENTE CASTERS ® WARNING: Casters must be locked at all times, except during transport. The Lumex Ortho-Biotic II Recliner features the latest black actuator tab green actuator tab design, all-plastic casters from TENTE. Specifically designed for use in healthcare environments, these casters are easier to clean, easier to move, and tolerate a wide array of cleaners and chemicals.
  • Page 8: Legrest Operation

    LEGREST OPERATION Legrest Extending Legrest (Shown Extended) To activate the legrest, pull the Legrest-Recline Adjustment Lever (located on the right side of the recliner) rearward — the legrest will extend out from the recliner. Returning Legrest to Stored Position To return the legrest to the stored position, press downward on Legrest-Recline Adjustment Lever the legrest until the legrest locks into place and is flush with the...
  • Page 9: Footplate Operation

    FOOTPLATE OPERATION The Lumex Ortho-Biotic II Recliner features a self-storing footplate for patient comfort and convenience during patient transport. The Optional IV Pole and Optional footplate is easily extended when needed and IV Attachment can be stored safely out of the way when not in use.
  • Page 10: Optional Accessories

    OPTIONAL ACCESSORIES The Lumex Ortho-Biotic II Recliner is available with several Factory Installed Optional Accessories. Optional Side Table An Optional Side Table is available for storage of prep materials or patient items. Order Item FR597GTBLMNT, Optional Side Table. Optional Side Table Operation Raising Side Table: Raise the side table all Optional the way up and slide in toward the armrest...
  • Page 11: Recliners With Heat And Massage Or Heat Only Feature

    RECLINERS WITH HEAT AND MASSAGE OR HEAT ONLY FEATURE HEAT AND MASSAGE: FR597GH / FR597PH; HEAT ONLY: FR597GHO / FR597PHO INSTALLATION AND OPERATING GUIDE Tools required: masking or packaging tape WARNING: Important! Read and understand these instructions before assembling or using the Specialty Healthcare Seating Heat and Massage / Heat Only Unit.
  • Page 12: Heat And Massage / Heat Only Installation Instructions

    Handheld Heat & Massage Power Cord Handheld Heat Only Power Cord Pendant Connectors Connector Pendant Connectors Connector Connector Connector Heat and Massage Feature — Heat Only Feature — Control Module and Transformer Unit Control Module and Transformer Unit Showing All Connections Correctly Made Showing All Connections Correctly Made 2.
  • Page 13 Insert Insert Seat Seat Connector Connector Here Here Heat and Massage Feature — Heat Only Feature — Install Seat Connector Install Seat Connector 4. There is only one connection to make — push the seat connector firmly into the control module until its locking tabs snap into place as shown above.
  • Page 14: Heat And Massage / Heat Only Unit Operation Instructions

    Heat and Massage / Heat Only Unit Operation Instructions 1. Plug the power cord into any grounded outlet. Handheld Pendant Handheld Pendant Heat and Massage Heat Only 2. The Heat and Massage / Heat Only Unit is operated using the Handheld Pendant, shown above. HIGH HEAT PRESS 1 TIME MEDIUM HEAT...
  • Page 15 4. Heat and Massage MASSAGE Option: Press the MASSAGE switch to start this function. The Massage Function Settings are as follows: a) Press selector switch for Setting 1: Gentle Lower Back Massage. b) Press selector switch AGAIN for Setting 2: Firm Lower Back Massage. c) Press selector switch AGAIN for Setting 3: Gentle Upper and Lower Back Massage.
  • Page 16: Heat And Massage / Heat Only Unit Troubleshooting Guide

    Heat and Massage / Heat Only Unit Troubleshooting Guide The cables and connections need to be validated. This will require the services of a maintenance person and a clear working area. 1. INSPECTION: Perform the following checks. If a working recliner of the same model is available, use it for comparison.
  • Page 17: Care And Maintenance

    CARE AND MAINTENANCE WARNING: Inspect all components every three months and replace as needed. EVERY THREE MONTHS • Check and clean casters. • Tighten bolts in each caster plate to ensure casters are secured tightly to frame. • Check caster brakes. •...
  • Page 18: Cdc Recommendations

    Info: Misuse of disinfectants is the major source of surface deterioration. Spradling International, Inc. continually evaluates cleaners/disinfectants, and a list of those tested can be found on their ® website. Abrasion test results exceeding ACT Performance Guidelines are not an indicator of product lifespan.
  • Page 19 • Avoid large-surface cleaning methods that produce mists or aerosols, or disperse dust in patient-care areas. • Follow proper procedures for effective uses of mops, cloths, and solutions. • Prepare cleaning solutions daily or as needed, and replace with fresh solution frequently according to facility policies and procedures.
  • Page 20: Disposal And Key To Symbols

    DISPOSAL AND KEY TO SYMBOLS DISPOSAL Lumex Recliner equipment and accessories can be disposed of. We recommend disassembling and dividing the equipment and components into different waste groups such as: metal, cable, electronic, recoverable resource and plastic for recycling or combustion.
  • Page 21: Test Parameters

    TEST PARAMETERS California Technical Bulletin CA TB133 Flammability Test ANSI / BIFMA X5.4-2013 Sections 11, 12, 14, and 18 TECHNICAL SPECIFICATIONS Specification Series FR597 Overall Height 45.5" 115.6 cm Overall Width 33" 83.8 cm Width Between Arms 24" 61 cm Arm Height from Floor 26.75"...
  • Page 22: Limited Warranty

    LIMITED WARRANTY SCOPE OF WARRANTY GF Health Products, Inc. (“GF”) warrants to the original purchaser only that it will replace or repair components, at GF’s sole discretion, that are defective in material or workmanship under normal use and service. All warranties are conditioned upon the proper use of the products strictly in accordance with good commercial practice and applicable GF instructions and manuals, including proper use and maintenance.
  • Page 23: Index

    INDEX Accessories, optional, operation 10 Operation 7 Accessories, optional, purchasing 21 Packaging 5 Care and maintenance 17 Caster, directional (swivel) 7 Recline operation 8 Caster operation 7 Recliner operation 7 Casters, locking 7 Reclining, by caregiver 8 CAUTION statement, significance 3 Reclining, by patient 8 Returning to upright position, by caregiver 8 Description and features 6...
  • Page 24 1.770.368.4700 Information contained herein is subject to change. The most current and complete product information can be found on our website. www.grahamfield.com © 2014, GF Health Products, Inc. All Rights Reserved. Lumex and Ortho-Biotic are trademarks of GF Health Products, Inc. Tente is a trademark of TENTE GmbH &...

Table of Contents