About This Document; General Safety Precautions; Electrical Connection - STEINEL Professional Series Instructions Manual

Hide thumbs Also See for Professional Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
GB

1. About this document

Please read carefully and keep in a safe place.
– Under copyright. Reproduction either in whole or
in part only with our consent.
– Subject to change in the interest of technical
progress.
Symbols
!
Hazard warning!
Reference to other information in
the document.
...

2. General safety precautions

Disconnect the power supply before
!
attempting any work on the unit.
• Installing these lights involves work on the mains
voltage supply; installation must therefore be
carried out professionally in accordance with the
applicable national wiring regulations and electri-
cal operating conditions (e.g.: DE: VDE 0100,
AT: ÖVE/ÖNORM E 8001-1, CH: SEV 1000).
• The floodlight enclosure heats up when the light
is on. Only adjust the angle of the LED head
once it has cooled down.
• The light must be positioned so that it is not
expected that anybody can look into the light
for any prolonged period from a distance of less
than 0.3 m.
3. XLED PRO Square XL S/ Wide XL S
Proper use
– Sensor-switched floodlight with LEDs as light
source.
– Suitable for wall mounting outdoors.
– Data line (D-line, optional) for synchronous
switching.
Non-intended use
– The sensor-switched LED floodlight cannot be
dimmed.
Not dimmable
Operating principle
The XLED PRO Square XL S and XLED PRO 
Wide XL S sensor-switched LED floodlights are
fitted with infrared sensors. These floodlights
provide a basic brightness function by means of
additional light lines.
In stand-alone mode, the slave version of this LED
floodlight must be switched ON and OFF via a
switch/button to be provided on site. As an option,
main and basic light can be switched ON and OFF
in synchrony via an additional data line (D-line)
between sensor-switched LED floodlights (master-
master) and slave LED floodlight (master-slave).
Models
– XLED PRO Square XL S
– XLED PRO Wide XL S
Package contents
XLED PRO Square XL S (Fig. 3.1)
XLED PRO Wide XL S (Fig. 3.3)
Product dimensions
XLED PRO Square XL S (Fig. 3.2)
XLED PRO Wide XL S (Fig. 3.4)
Product components (Fig. 3.5)
A
Floodlight head
B
Basic light level LED
C
Enclosure
D
Function setting
- Basic light level
- Time setting
- Twilight setting
Status LED
E
F
IR sensor
G
Cover on controls
H
Wall mount
Plug connection
I
Luminous intensity distribution (Fig. 3.6 - 3.7)

4. Electrical connection

Connecting the mains power supply lead
(Fig. 5.5)
The mains power supply lead is a 3-core cable:
= phase conductor
L
(usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
D = D-line (data line) optional