EN
A
Figure2.
Mechanical ventilation
Joonis 2.
Mehaaniline ventilatsioon
4. INSTALLATION INSTRUCTIONS
Read the entire installation instructions carefully
before beginning installation!
4.1. Installation location and safety distances
Do not install the radiator at head level (Figure 3).
•
The lateral distance between radiators must be
•
at least 150 mm.
The distance between the radiator's front
•
surface and the burning materials must be at
least 50 mm, excluding the protective grate 20
mm (Figure 5).
Leave 15 mm of open well-ventilated space
•
behind the radiator (Figure 4b).
Do not install the radiator above the sauna
•
heater.
Leave a lateral clearance of 800 mm between
•
the heater and radiator.
There must be a minimum distance of 200 mm
•
between the radiator and the ceiling or floor.
See Figure 4c for the recommended distance
•
from the bottom edge of the installation
opening to the top bench.
DIR-350-R-F
WIR-350-R-F
Figure 3.
Joonis 3.
C
D
B
min. 800 mm
DIR-500-R-F
WIR-500-R-F
min. 900 mm
ET
A
Natural ventilation
Loomulik ventilatsioon
4. PAIGALDUSJUHISED
Enne paigaldamist lugege paigaldusjuhised
hoolikalt läbi!
4.1. Paigalduskoht ja ohutuskaugused
Ärge paigaldage radiaatoreid pea kõrgusele
•
(joonis 3).
Radiaatorite omavaheline kaugus peab
•
külgsuunas olema vähemalt 150 mm.
Radiaatori pealispinna ja süttiva materjali
•
vaheline kaugus peab olema vähemalt 50 mm,
välja arvatud kaitserest 20 mm (joonis 5).
Radiaatori taha peab jääma 15 millimeetrit
•
vaba, hea ventilatsiooniga ruumi (joonis 4b).
Ärge paigaldage radiaatorit kerise kohale.
•
Kerise ja radiaatori vahele peab külgsuunas
•
jääma 800 mm.
Infrapunaradiaatori ja lae või põranda vahele
•
peab jääma vähemalt 200 millimeetrit.
Paigaldusava alumise serva soovitatav kaugus
•
ülemisest saunalavast on esitatud joonisel 4 c.
C
D
B
17