3.1. Prior to Installation

Prior to installing the heater, read all the instructions
for installation (figure 7), as well as checking the fol-
lowing points:
The heater volume should be suitable for the
sauna room volume. Table 2 shows the mini-
mum and maximum volumes for each heater
output. A precondition for the given values is that
the sauna room is well heatinsulated. Walls and
ceiling are covered with wood panel.
Check that supply voltage and amperages are
available for the heater.
The breakers and the connection cables con-
form with valid regulations and their dimen-
sions are in accordance with table 3.
The location is suitable for the heater ( 3.2.).
3.7. Resetting the Overheat Protector
A min.
B min.
0,8''
3,1''
A
min. 0,4''
Figure 5.
Minimum safety distances
Heater
Output
kW
HCBU1712241
1,7
HCBU1912241
1,9
HCBU352401
3,5
Table 2.
Installation details of the heater

3. INSTRUCTIONS FOR INSTALLATION

A
3,1'' - 7,8''
Dimensions
Width/Depth/
Weight
Height
inch
mm
lb/kg
11/11/21
15,4 7
280/280/535
11/11/21
15,4 7
280/280/535
11/11/21
16,1 7,3 28,5 13
280/280/535
EN

3.2. Place and Safety Distances

The minimum safety distances are described in
figure 4 and 5.
It is absolutely necessary to install the heater
according to these values. Neglecting them
causes a risk of fire. ( 3.6.)
Hot pieces of stone can damage floor coverings
and cause a risk of fire. The floor coverings of
the installation place should be heat-resistant.

3.3. Heater fence

It is necessary for safety and should be constructed
of softwood to match sauna interior. See figures 4
and 5 for clearances from sauna heater. Fence should
be attached to wall and should not be placed higher
than top of heater below rock line.
B
min. 0,4''
Stones
Sauna room
Cubic vol.
2.3.!
max.
min.
lb/kg
CuFt/m³
28,5 13
70,5 2
28,5 13
70,5 2
70,5 2
Height
Floor Area
max.
min
max
CuFt/m³
sqft
sqft
inch/mm
106 3
11,3 17
75 1900
106 3
11,3 17
75 1900
175 5
11,3 28
75 1900
min.