Setting The Analog Output Unit; List Of Analog_4Out Parameters - Panasonic GM1 Series Reference Manual

Motion controller
Hide thumbs Also See for GM1 Series:
Table of Contents

Advertisement

4.4 Setting the Analog Output Unit

4.4 Setting the Analog Output Unit

4.4.1 List of Analog_4OUT Parameters

The following table shows a list of changeable parameters for the GM1 Analog Output Unit.
Set parameter for each channel.
Parameter
OutputProcess
RangeSetting
AnalogOutputAtStop
OutputValueAtStop
OffsetGainProcess
OffsetValue
GainValue
ScaleConversion
ScaleConversionMaxValue
ScaleConversionMinValue
UpperAndLowerOutputClipping
4-10
Default
Settings
Output
Select "Output / No output" of the analog output.
Select the output range.
-10 to +10 V
0 to +10 V
-5 to +5 V
-10 V to +10 V
0 to +5 V
+1 to +5 V
0 to +20 mA
+4 to +20 mA
Select the operation of the analog output hold function
Hold with user-
in the STOP mode.
specified value
Hold with user-specified value / Hold at current value
Specify the output value when OutputValueAtStop is
set to "Desired output value".
-32640 to +32640
0
0 to +32640
0 to +25600
Select "Output / No output" for the Offset / Gain
No output
processing.
Specify the offset value for when the Offset / Gain
processing is executed.
0
-3000 to +3000
Specify the gain value for when the Offset / Gain
10000
processing is executed.
(multiplied by 1.0)
+9000 to +11000 (multiplied by 0.9 to 1.1)
No output
Select "Output / No output" of the scale conversion.
Specify the maximum value after scale conversion is
executed.
10000
-32768 to +32767
Specify the minimum value after scale conversion is
executed.
0
-32768 to +32767
No output
Select "Output / No output " of the clipping function.
(For -10 to +10 V, -5 to +5 V range)
(For 0 to +10 V, 0 to +5 V, 0 to +20 mA)
(For +1 to +5 V, +4 to +20 mA)